LBi-2.1: Material Emissions: Adhesives & Sealants<br />

Intent Confirm the use of low emission adhesives and sealants to encourage the desirability of<br />

these spaces in relation to improved occupant health.<br />

Credit<br />

Requirements GENERAL<br />

Awarding<br />

Credit Points<br />

Credit<br />

Submission:<br />

Design <strong>Rating</strong><br />

Credit<br />

Submission:<br />

Construction<br />

<strong>Rating</strong><br />

Demonstrate that a minimum of 95% (by weight) of all adhesives and sealants used on the<br />

building interior must not exceed the prescribed VOC limits in South Coast Air Quality<br />

Management District Rule 1168, some of which are reproduced in the table below.<br />

The VOC limits of the remaining non compliant adhesives and sealants must be no more<br />

than 50% higher than values listed for each product type.<br />

Product Type<br />

Maximum grams of VOC per liter of<br />

adhesive or sealant, less water and<br />

exempt compounds<br />

Indoor Carpet Adhesive 50<br />

Carpet Pad Adhesive 50<br />

Wood flooring Adhesive 100<br />

Rubber flooring Adhesive 60<br />

Sub-floor adhesive 50<br />

Ceramic tile adhesive 65<br />

Cove base adhesive 50<br />

Plasterboard and wall panel adhesive 50<br />

Multipurpose construction adhesive 70<br />

Structural glazing adhesive 100<br />

Architectural sealants 250<br />

ADDITIONAL REQUIREMENT/CLARIFICATIONS<br />

Schools<br />

100% of all adhesives and sealants must be compliant.<br />

CREDIT POINTS REQUIREMENTS<br />

1<br />

(maximum)<br />

1<br />

1<br />

(maximum)<br />

1<br />

Design <strong>Rating</strong><br />

95% of all adhesives & sealants meet criteria; or<br />

Schools : 100% of all adhesives & sealants meet criteria<br />

Construction <strong>Rating</strong><br />

95% of all adhesives & sealants meet criteria; or<br />

Schools : 100% of all adhesives & sealants meet criteria<br />

� Narrative with extracts from specifications for all interior adhesives and sealants in<br />

relation to the project confirming which products will and will not comply with the<br />

requirements. Establish estimates for quantities of products likely to be used in the<br />

case where projects are aiming to meet the VOC limits for 95% of products and enter<br />

these into the LBi-2.1 Adhesives and Sealants template.<br />

� Billing/purchase receipts for all interior adhesives and sealants used in the project;<br />

� Tracking sheet, signed by the construction managers for receipt of all adhesives and<br />

sealants;<br />

� Enter all compliant and non-compliant adhesives and sealants into the LBi-2.1 Adhesives<br />

<strong>Pearl</strong> <strong>Building</strong> <strong>Rating</strong> <strong>System</strong>: Design & Construction, Version 1.0, April 2010 84 of 223