Pearl Building Rating System - Estidama
Pearl Building Rating System - Estidama
Pearl Building Rating System - Estidama
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
LBo-10: Light Pollution Reduction<br />
Intent To encourage the reduction of night time light pollution and its associated impacts on<br />
human and ecological health.<br />
Credit<br />
Requirements<br />
GENERAL<br />
Demonstrate that the project meets the following lighting requirements:<br />
Interior lighting<br />
� The angle of maximum candela from each interior luminaire, as positioned in the<br />
building, must not exit through the windows. Alternatively, all non-emergency<br />
interior lighting must be controlled to automatically turn off outside the normal<br />
hours of occupancy. Manual override must be enabled to allow for any out-of-hours<br />
use.<br />
Exterior lighting<br />
� All non safety and security external lighting, including display, advertising and<br />
speciality lighting, must be automatically switched off between 23.00hrs and<br />
07.00hrs and outside these hours if daylight levels are sufficient.<br />
o If safety lighting is provided and will be used between 23.00hrs and<br />
07.00hrs, this part of the lighting system must comply with the lower levels<br />
of lighting recommended during these hours by IESNA RP-33-99 and IES RP-<br />
8. For example by using an automatic switch to reduce the lighting levels<br />
at 23.00 or earlier.<br />
o If security lighting is provided, it must be activated using motion sensors so<br />
that luminaires only turn on when someone is in the immediate area.<br />
Lighting levels at the boundary and beyond<br />
� All projects must be classified under one of the zones defined in the IECC 2009<br />
Exterior Lighting Table 505.6.2(1). The exterior lighting must be designed to meet<br />
the following requirements:<br />
Lighting Zone<br />
LZ1:<br />
Parks and rural<br />
areas<br />
LZ2:<br />
Residential areas<br />
LZ3:<br />
All other areas<br />
Maximum Initial<br />
Illuminance at Site<br />
Boundary, Lux<br />
Maximum Initial<br />
Illuminance at<br />
Specified Distance<br />
Beyond Site<br />
Boundary, Lux<br />