LBi-R2: Smoking Control<br />

Intent To eliminate or minimize exposure of building occupants to the harmful effects of<br />

tobacco smoke.<br />

Credit<br />

Requirements<br />

Requirement<br />

Achievement<br />

Credit<br />

Submission:<br />

Design <strong>Rating</strong><br />

Credit<br />

Submission:<br />

Construction<br />

<strong>Rating</strong><br />

GENERAL<br />

Demonstrate appropriate measures are incorporated into the building design to reduce<br />

exposure to tobacco smoke:<br />

� Demonstrate that smoking is prohibited throughout the building(s) including car<br />

parks;<br />

� Establish 25m smoke free zones around all entrances, outdoor air intakes and<br />

operable windows;<br />

� Train all security staff for smoking control within and outside buildings;<br />

� Locate any dedicated external smoking areas away from public or high use<br />

pedestrian thoroughfares and install suitable facilities for collecting ash and<br />

cigarette ends; and<br />

� Install signage that at a minimum lists the negative health impacts of smoking and<br />

provides details on where to seek assistance for those aiming to stop smoking,<br />

visible in all dedicated external smoking areas.<br />

ADDITIONAL REQUIREMENT/CLARIFICATIONS<br />

Residential<br />

� All residential units must be sealed with impermeable deck to deck partitions along<br />

the whole perimeter of the unit. All penetrations in walls, floors and ceilings must<br />

be sealed. All internal doors leading from residential units to common areas or<br />

between residential units must be weather-stripped. No smoking will be permitted<br />

within any and all common areas of the building including car parks.<br />

� Establish 25m smoke free zones around all entrances, outdoor air intakes and<br />

operable windows.<br />

Schools<br />

� Smoking must be prohibited throughout school buildings and associated school<br />

grounds.<br />

This is a requirement. There are no Credit Points awarded.<br />

� Written commitment from the building owner/developer that there will be a no<br />

smoking policy operated within the building (or common areas for residential<br />

buildings or additionally for school grounds) by inclusion in Contracts of Sale and<br />

Lease/Rent Agreements that smoking will be banned by future owners and tenants;<br />

� Extracts from specifications and/or drawings indicating the locations of posted<br />

signage stating that the entire building is a no smoking environment and detailing<br />

the negative health impacts of smoking installed in all dedicated external smoking<br />

areas;<br />

� Drawings indicating the location of dedicated outside smoking areas and facilities<br />

for collecting ash and cigarette ends which clearly indicate their distance from<br />

entrances, operable windows and air intakes; and<br />

� For residential units, provide specifications for weather-stripping of doors and<br />

drawings that highlight impermeable deck to deck partitioning.<br />

� Updated written commitment (if relevant) from the building owner / developer that<br />

there is a no smoking policy operated within the building (or common areas for<br />

residential buildings or additionally for school grounds) by inclusion in Contracts of<br />

Sale and Lease/Rent Agreements that smoking will continue to be banned by future<br />

owners and tenants;<br />