RE-6: Renewable Energy<br />

Intent To reward projects for the use of renewable technologies, therefore reducing the<br />

carbon emissions associated with building operation and the reliance on fossil fuel<br />

based power generation.<br />

Credit<br />

Requirements<br />

Awarding Credit<br />

Points<br />

Credit<br />

Submission:<br />

Design <strong>Rating</strong><br />

GENERAL<br />

Demonstrate that a percentage of the developments total energy demand is supplied<br />

through renewable energy.<br />

Onsite <strong>System</strong>s:<br />

� Demonstrate that an onsite renewable energy feasibility study has been undertaken,<br />

and that one or more appropriate technologies have been selected as a result of the<br />

study; and<br />

� 1-8 Credit Points: Demonstrate that a percentage of the proposed buildings energy<br />

consumption is supplied through onsite renewable energy. Points are awarded as<br />

follows:<br />

Points<br />

Achieved<br />

Required<br />

Percentage<br />

1 1%<br />

2 3%<br />

3 5%<br />

4 7%<br />

5 10%<br />

6 13%<br />

7 16%<br />

8 20%<br />

Offsite <strong>System</strong>s:<br />

� 1 Credit Point: Demonstrate that a minimum of 20% of the project’s non-renewable<br />

energy use will be provided by offsite renewable generation through direct purchase<br />

and/or certified Renewable Energy Certificates (RECs), and that contracts are signed<br />

for a minimum of 2 years.<br />

ADDITIONAL REQUIREMENT/CLARIFICATIONS<br />

None<br />

.<br />

CREDIT POINTS REQUIREMENTS<br />

9<br />

(maximum)<br />

1-8<br />

1<br />

9<br />

(maximum)<br />

1-8<br />

1<br />

Design <strong>Rating</strong><br />

Demonstrate that a percentage of the total energy consumption<br />

will be supplied by onsite renewable energy.<br />

Demonstrate that 20% of the project’s non-renewable energy use<br />

will be supplied by offsite renewable energy.<br />

Construction <strong>Rating</strong><br />

Demonstrate that a percentage of the total energy consumption is<br />

supplied by onsite renewable energy.<br />

Demonstrate that 20% of the project’s non-renewable energy use<br />

is supplied by offsite renewable energy.<br />

Onsite <strong>System</strong>s:<br />

� Renewable energy feasibility study covering each of the technologies required as<br />

well as recommendations on the preferred technology/technologies; and<br />

� Calculations of the annual energy generation capability of each proposed<br />

renewable energy technology, both in terms of annual energy produced as well as a<br />

<strong>Pearl</strong> <strong>Building</strong> <strong>Rating</strong> <strong>System</strong>: Design & Construction, Version 1.0, April 2010 163 of 223