01.06.2013 Views

Wellgreen Project Preliminary Economic Assessment ... - OTCIQ.com

Wellgreen Project Preliminary Economic Assessment ... - OTCIQ.com

Wellgreen Project Preliminary Economic Assessment ... - OTCIQ.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Recovery, %<br />

Recovery, %<br />

100<br />

80<br />

60<br />

40<br />

20<br />

Prophecy Platinum Corporation – <strong>Wellgreen</strong> Property – <strong>Project</strong> 50149-001<br />

Rougher Kinetics, Cu<br />

0<br />

0 5 10 15 20 25 30<br />

100<br />

80<br />

60<br />

40<br />

20<br />

Mass Recovery, %<br />

Rougher Kinetics, Pt<br />

0<br />

0 5 10 15 20 25 30<br />

Mass Recovery, %<br />

Recovery, %<br />

100<br />

4.1.1.1. Effect of Primary Grinding<br />

80<br />

60<br />

40<br />

20<br />

100 g/t SIPX<br />

80 g/t PAX<br />

70 g/t SIPX<br />

Higher pH<br />

50 um<br />

150 um<br />

Talc pre-float<br />

CMC<br />

100 g/t SIPX<br />

80 g/t PAX<br />

70 g/t SIPX<br />

Higher pH<br />

50 um<br />

150 um<br />

Talc pre-float<br />

CMC<br />

Recovery, %<br />

Recovery, %<br />

100<br />

80<br />

60<br />

40<br />

20<br />

SGS Minerals Services<br />

Rougher Kinetics, Ni<br />

0<br />

0 5 10 15 20 25 30<br />

100<br />

80<br />

60<br />

40<br />

20<br />

Rougher Kinetics, Au<br />

0<br />

0 5 10 15 20 25 30<br />

Mass Recovery, %<br />

Mass Recovery, %<br />

Rougher Kinetics, Pd<br />

0<br />

0 5 10 15 20 25 30<br />

100 g/t SIPX<br />

80 g/t PAX<br />

70 g/t SIPX<br />

Higher pH<br />

50 um<br />

150 um<br />

Talc pre-float<br />

CMC<br />

Mass Recovery, %<br />

Figure 16: Effect of Mass Recovery on Cu, Ni and PGE Recovery<br />

100 g/t SIPX<br />

80 g/t PAX<br />

70 g/t SIPX<br />

Higher pH<br />

50 um<br />

150 um<br />

Talc Pre-float<br />

CMC<br />

100 g/t SIPX<br />

80 g/t PAX<br />

70 g/t SIPX<br />

Higher pH<br />

50 um<br />

150 um<br />

Talc Pre-float<br />

<strong>Preliminary</strong> rougher kinetics tests were conducted on the <strong>com</strong>posite sample to determine the effects of<br />

grind size. Tests F3, F5, and F6 varied the primary grind, at 90, 50, and 144 microns respectively, while<br />

the SIPX dosage remained constant at 70 g/t at natural pH. In test F8 CMC was used as talc depressant.<br />

The results are shown in Figures 17 and 18.<br />

CMC<br />

23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!