11.0 SAMPLE PREPARATION, ANALYSES,<br />

AND SECURITY<br />

This section describes the Prophecy Platinum 2010 to 2011 Sample Preparation,<br />

Analyses and Security Program as well as the QA/QC program.<br />

11.1 S AMPLE P REPARATION AND A NALYSES P ROGRAM<br />

Samples were taken into the Prophecy Platinum geological office in sealed bags, by<br />

<strong>com</strong>pany personnel. This secure office where the samples were stored, was only<br />

accessible by the geologist and camp manager. When enough samples were<br />

accumulated, <strong>com</strong>pany personnel packed the samples into rice bags, labelled them,<br />

and took the bags to the ALS Minerals preparation facility in Whitehorse.<br />

All samples, including field-inserted Standards and Blanks, were sent to ALS<br />

Minerals in Vancouver, BC, for assaying. ALS Minerals has ISO/IEC 17025:2005<br />

and ISO 9001:2000 certification.<br />

The samples were assayed for copper, nickel, cobalt, gold, platinum, and palladium.<br />

The following is a brief description of the sample preparation:<br />

1. Samples are sorted into numerical order and then dried.<br />

2. Once dried, the material was crushed using a jaw crusher.<br />

3. The sample is then split to get a 250 g sample for pulverizing.<br />

4. The total 250 g of split sample is pulverized to 85% passing 75 μm.<br />

Gold, platinum, palladium were assayed by fire assay fusion of 30 g with an ICP<br />

finish. The resulting values were reported in parts per million.<br />

Copper, nickel, and cobalt were assayed by four-acid “near total” digestion AAS. If<br />

any of the assays returned values above the detection limits, the sample was reassayed<br />

using a similar method (ICP-AES or AAS).<br />

At no time was a Prophecy Platinum employee or designate of the <strong>com</strong>pany involved<br />

in the preparation or analysis of the samples.<br />