01.06.2013 Views

Wellgreen Project Preliminary Economic Assessment ... - OTCIQ.com

Wellgreen Project Preliminary Economic Assessment ... - OTCIQ.com

Wellgreen Project Preliminary Economic Assessment ... - OTCIQ.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Prophecy Platinum Corporation – <strong>Wellgreen</strong> Property – <strong>Project</strong> 50149-001<br />

Rougher flotation test HNI-F1 was conducted using the same conditions as the rougher flotation test F3<br />

for the Master Composite. Mass recovery and Cu and Ni recoveries were higher for high Ni <strong>com</strong>posite.<br />

The results for HNI-F1 are shown in Table 22. Detailed test conditions and results and are presented in<br />

Appendix E.<br />

Table 22: Rougher Flotation Test HNI-F1 Results<br />

Test Product Weight Assays, (Pt, Pd, Au g/t), (Cu, Ni, S %)<br />

% Distribution<br />

% Cu Ni S Pt Pd Au Cu Ni S Pt Pd Au<br />

Ro Conc 1 2.3 1.10 0.44 3.00 0.58 4.02 0.23 4.8 1.2 1.0 2.3 16.9 8.5<br />

HNI-F1 Ro Conc 1-2 6.4 6.32 1.77 11.2 1.46 4.14 0.50 75.8 13.6 10.8 16.2 48.0 51.4<br />

SIPX 70 g/t Ro Conc 1-3 13.2 3.59 4.69 15.0 1.60 3.02 0.32 88.7 74.3 29.8 36.7 72.1 66.6<br />

K80 90 um Ro Conc 1-4 18.4 2.67 3.69 15.9 1.67 2.37 0.24 91.9 81.3 43.9 53.0 78.6 71.5<br />

Ro Conc 1-5 26.2 1.92 2.77 17.1 1.50 1.77 0.18 94.1 86.7 67.4 68.1 84.0 76.5<br />

Ro Tail 73.8 0.04 0.15 2.94 0.25 0.12 0.02 5.9 13.3 32.6 31.9 16.0 23.5<br />

Head ( calc. ) 0.53 0.83 6.66 0.58 0.55 0.06<br />

Cleaner flotation test HNI-F2 was conducted using the same test conditions as the master <strong>com</strong>posite<br />

cleaner flotation test F12. High Ni <strong>com</strong>posite has a higher sulphide content which would result in a<br />

proportionally higher mass flow to the cleaning circuit. Ni recovery was high at 66.5% for this <strong>com</strong>posite<br />

as <strong>com</strong>pared to 48.5% for Master Composite. Based on the test HNI-F2, a 15% Cu+Ni concentrate grade<br />

was achieved; the Cu and Ni recoveries were 85% and 66.5%, respectively. The <strong>com</strong>bined Au, Pt, and<br />

Pd grade of this test was 9 g/t. The Pt, Pd and Au recoveries were 29%, 66% and 61%, respectively. The<br />

Fe/MgO ratio and MgO content of the final concentrate were within the accepted limits in this test.<br />

The results for test HNI-F2 are shown in Table 23. Detailed test conditions and results and are presented<br />

in Appendix E.<br />

Table 23; Cleaner Flotation Test HNI-F2 results<br />

Test<br />

Product<br />

Weight<br />

% Cu<br />

Assays, (Pt, Pd, Au g/t), (Cu, Ni, Fe, MgO %)<br />

Ni S Pt Pd Au Fe MgO Cu Ni<br />

% Distribution<br />

S Pt Pd Au Fe MgO<br />

3rd Clnr Conc 6.8 6.53 8.21 25.0 2.53 5.54 0.68 36.0 3.02 85.2 66.5 27.1 29.1 65.6 61.5 13.4 1.0<br />

HNI-F2 2nd Clnr Conc 10.2 4.54 6.24 23.7 2.36 4.18 0.51 36.6 5.18 88.9 75.7 38.5 40.7 74.2 69.2 20.4 2.5<br />

No Regrind 1st Clnr Conc 15.7 3.01 4.30 19.7 1.89 2.87 0.36 32.9 9.84 90.6 80.2 49.1 50.0 78.2 75.8 28.2 7.4<br />

CMC=200 g/t 1st Cl & ClScv Conc 17.0 2.79 4.02 19.3 1.84 2.68 0.34 32.9 10.2 91.0 81.3 52.2 52.8 79.2 77.2 30.5 8.3<br />

Rghr Conc 22.2 2.15 3.15 16.1 1.54 2.10 0.27 29.4 12.8 91.6 83.3 57.1 57.9 81.0 79.3 35.7 13.6<br />

1st Clnr Scv Tls 5.2 0.07 0.33 5.88 0.58 0.20 0.03 18.3 21 0.7 2.1 4.9 5.1 1.8 2.1 5.2 5.3<br />

Rougher Tails 77.8 0.06 0.18 3.46 0.32 0.14 0.02 15.1 23.2 8.4 16.7 42.9 42.1 19.0 20.7 64.3 86.4<br />

Head ( calc. ) 0.52 0.84 6.27 0.59 0.57 0.08 18.3 20.9<br />

Flotation tests HNI-F3 to HNI-F5 tested the split flowsheet for this <strong>com</strong>posite.<br />

Test HNI-F3 was conducted as per the master <strong>com</strong>posite flotation test F-35. Higher Ni grade and<br />

recovery at 11% and 42% respectively, were achieved in this test.<br />

HNI-F4 was conducted with longer rougher and scavenger flotation time with no bulk cleaner re-grind.<br />

Almost the same Cu and Ni grade-recovery relationships were achieved in this test. The Fe/MgO ratio<br />

and MgO content of the final concentrates were within the accepted limits in both tests.<br />

The results for HNI-F3 and HNI-F4 are shown in Table 24. Detailed test conditions and results and are<br />

presented in Appendix E.<br />

SGS Minerals Services<br />

48

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!