01.06.2013 Views

Wellgreen Project Preliminary Economic Assessment ... - OTCIQ.com

Wellgreen Project Preliminary Economic Assessment ... - OTCIQ.com

Wellgreen Project Preliminary Economic Assessment ... - OTCIQ.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Prophecy Platinum Corporation – <strong>Wellgreen</strong> Property – <strong>Project</strong> 50149-001<br />

Table 18: Test F-39 Results Using MF2 Flowsheet<br />

Product Weight Assays, % % Distribution<br />

% Cu Ni S Cu Ni S<br />

Prim Clnr 2 Conc 1.0 15.5 7.28 29.7 40.9 14.9 8.57<br />

Prim Clnr 1 Conc 1.3 11.6 7.95 28.1 42.9 22.8 11.4<br />

Prim Rougher Conc 4.8 3.75 4.56 16.1 49.1 46.4 23.1<br />

Sec Clnr 2 Conc 2.6 5.31 4.20 20.7 37.6 23.1 16.1<br />

Sec Clnr 1 Conc 4.5 3.19 2.82 16.4 39.8 27.3 22.5<br />

Sec Scav Conc 9.9 1.53 1.51 11.1 41.5 31.8 33.0<br />

Regrind Scav Conc 0.2 0.65 0.98 7.80 0.38 0.45 0.50<br />

Regrind Scav Feed 5.3 0.11 0.39 6.55 1.65 4.50 10.5<br />

Regrind Scav Tail 5.1 0.09 0.37 6.50 1.27 4.05 10.0<br />

Sec Scav Tail 85.3 0.04 0.12 1.71 9.38 21.8 43.9<br />

Comb Clnr Conc 3.5 8.07 5.04 23.1 78.5 38.0 24.6<br />

Comb Ro & Scav Conc 14.7 2.25 2.50 12.7 90.6 78.2 56.1<br />

4.2.3. Locked Cycle Tests – Split Stream<br />

Locked cycle testing helps to establish plant predicted grade-recovery relationships since it includes<br />

circulating loads in a simulated continuous environment. Based on the results and analysis of<br />

metallurgical performance from the split flowsheet batch tests three locked cycle tests, LCT-1, LCT-3, and<br />

LCT-5 were conducted using this flowsheet (Figure 26) by re-circulating the intermediate products.<br />

LCT-1 was conducted with Cu-Ni separation on the last three cycles. In this test 4-kg charges were used<br />

for each cycle. A copper concentrate with a grade of 23% Cu at a recovery of 68% was achieved in this<br />

test. The Fe/MgO ratio and MgO content of the final concentrate were within the accepted limits in this<br />

test.<br />

Table 19 presents the locked cycle test (LCT-1) results, and detailed results are presented in Appendix F.<br />

Table 19: LCT-1 Test Results<br />

LCT-1 Weight<br />

Assays % Distribution<br />

Product % Cu Ni S Pt Pd Au Rh Ru Ir Os Co Fe MgO Cu Ni S Fe MgO<br />

% % % g/t g/t g/t ppb ppb ppb ppb % % %<br />

Cu Conc 1.00 23.2 0.88 28.3 2.16 4.83 1.44 177 192 150 140 0.045 28.5 2.83 68.2 1.8 9.5 2.3 0.1<br />

Cu Rougher Tail (Ni Conc.) 1.78 2.55 14.4 26.7 3.34 10.9 0.32 323 455 329 270 0.870 32.5 4.55 13.4 53.9 16.1 4.7 0.4<br />

Ni 3rd Clnr Conc 0.48 3.24 7.03 27.2 5.72 5.9 0.43 311 430 338 290 0.360 41.8 5.04 4.6 7.0 4.4 1.6 0.1<br />

Ni 1st Clnr Tail 15.0 0.13 0.48 7.48 1.02 0.61 0.05 90 112 106 72 0.023 18.5 20.4 5.8 15.0 38.0 22.5 13.5<br />

Ni Scav Tail 81.7 0.03 0.13 1.15 0.22 0.09 0.02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!