4 Communications via PROFIBUS DP 02.99 05.03<br />

4.2 Process data (PZD area)<br />

4.2.2 Description of the status signals (data from the drive)<br />

Status word (ZSW)<br />

(pos mode)<br />

4-100<br />

The slave signals its current status to the master using the status word<br />

(ZSW).<br />

Table 4-8 Structure of the status word (ZSW) in the pos mode<br />

Load power supply available/load power supply failed<br />

Within the traversing block / outside the traversing block<br />

Drive moving/drive stationary<br />

Setpoint/traversing task acknowledged (edge)<br />

Reference point set/ no reference point set<br />

Reference position reached/outside reference position<br />

Control requested/ local control<br />

No following error /following error<br />

Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0<br />

Warning present / no warning present<br />

Power–on inhibit / no power–on inhibit<br />

No OFF 3 present / OFF 3 present<br />

No OFF 2 present / OFF 2 present<br />

Note:<br />

Fault present / no fault present<br />

Operation enabled / operation inhibited<br />

1 signal / 0 signal<br />

Ready or no fault<br />

Ready to power–up / not ready to power–up<br />

Table 4-9 Description of the individual signals in the status word (ZSW) in the pos mode<br />

Bit Signal name Signal status, signal description<br />

0<br />

Ready to power–up /<br />

1 Power supply powered–up<br />

not ready to power–up 0 Not ready to power–up<br />

1 Ready or no fault<br />

2<br />

3<br />

4<br />

1 Ready<br />

0 Not ready<br />

Operation enabled /<br />

1 Operation enabled<br />

operation inhibited 0 Operation inhibited<br />

Fault present /<br />

no fault present<br />

(refer to Chapter 6.2)<br />

1 The drive is faulted and not operational.<br />

The drive goes into the power–on inhibit after the fault has<br />

been successfully removed and acknowledged.<br />

Which faults are present?<br />

––> refer to P947 (faults)<br />

and<br />

––> P954 (supplementary information, faults/warnings)<br />

0 No fault present<br />

No OFF 2 present /<br />

1 No OFF 2 present<br />

OFF 2 present 0 OFF 2 command present<br />