4 Communications via PROFIBUS DP 02.99 05.03<br />
4.2 Process data (PZD area)<br />
4.2.2 Description of the status signals (data from the drive)<br />
Status word (ZSW)<br />
(pos mode)<br />
4-100<br />
The slave signals its current status to the master using the status word<br />
(ZSW).<br />
Table 4-8 Structure of the status word (ZSW) in the pos mode<br />
Load power supply available/load power supply failed<br />
Within the traversing block / outside the traversing block<br />
Drive moving/drive stationary<br />
Setpoint/traversing task acknowledged (edge)<br />
Reference point set/ no reference point set<br />
Reference position reached/outside reference position<br />
Control requested/ local control<br />
No following error /following error<br />
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0<br />
Warning present / no warning present<br />
Power–on inhibit / no power–on inhibit<br />
No OFF 3 present / OFF 3 present<br />
No OFF 2 present / OFF 2 present<br />
Note:<br />
Fault present / no fault present<br />
Operation enabled / operation inhibited<br />
1 signal / 0 signal<br />
Ready or no fault<br />
Ready to power–up / not ready to power–up<br />
Table 4-9 Description of the individual signals in the status word (ZSW) in the pos mode<br />
Bit Signal name Signal status, signal description<br />
0<br />
Ready to power–up /<br />
1 Power supply powered–up<br />
not ready to power–up 0 Not ready to power–up<br />
1 Ready or no fault<br />
2<br />
3<br />
4<br />
1 Ready<br />
0 Not ready<br />
Operation enabled /<br />
1 Operation enabled<br />
operation inhibited 0 Operation inhibited<br />
Fault present /<br />
no fault present<br />
(refer to Chapter 6.2)<br />
1 The drive is faulted and not operational.<br />
The drive goes into the power–on inhibit after the fault has<br />
been successfully removed and acknowledged.<br />
Which faults are present?<br />
––> refer to P947 (faults)<br />
and<br />
––> P954 (supplementary information, faults/warnings)<br />
0 No fault present<br />
No OFF 2 present /<br />
1 No OFF 2 present<br />
OFF 2 present 0 OFF 2 command present<br />