5 Description of the Functions 02.99 04.01 <strong>08</strong>.03<br />
5.6 Parameters for SIMODRIVE POSMO A<br />
P0003 / 03 Gearbox step-down ratio<br />
300W<br />
Min Standard Max Unit Data type Effective<br />
–200000 1 200000 – C4 immed.<br />
The step-down ratio should be entered in accordance with the gear used.<br />
Note:<br />
P3 = 0 is not permissible.<br />
Sign change ––> direction of rotation change<br />
This parameter has a gearbox-dependent factory default.<br />
The following applies before SW 1.3: Min. value = 0.0001<br />
The following applies from SW 1.6:<br />
With a modulo axis (P1 > 0), the gear reduction ratio is limited by the path per gear revolution<br />
and the axis type.<br />
The following formula applies:<br />
F = Conversion factor (mm –> F = 1 ; inch –> F = 25.4)<br />
|P3| < 2147483647 * P2 / (F * 4096 * P1)<br />
075W<br />
Min Standard Max Unit Data type Effective<br />
–200000 1 200000 – C4 immed.<br />
The step-down ratio should be entered in accordance with the gear used.<br />
Note:<br />
P3 = 0 is not permissible.<br />
Sign change ––> direction of rotation change<br />
This parameter has a gearbox-dependent factory default.<br />
The following applies before SW 1.3: Min. value = 0.0001<br />
The following applies from SW 1.6:<br />
With a modulo axis (P1 > 0), the gear reduction ratio is limited by the path per gear revolution<br />
and the axis type.<br />
The following formula applies:<br />
F = Conversion factor (mm –> F = 1 ; inch –> F = 25.4)<br />
|P3| < 2147483647 * P2 / (F * 816 * P1)<br />
P0004 / 04<br />
300W 075W<br />
Dimension units<br />
Min Standard Max Unit Data type Effective<br />
0 0 2 – I2 immed.<br />
Dimension units for parameter values (0 = mm, 1 = degree, 2 = inch).<br />
P0005 / 05<br />
300W 075W<br />
Reference point coordinate<br />
Min Standard Max Unit Data type Effective<br />
–200000 0 200000 MSR C4 immed.<br />
The parameter specifies the position at the reference point.<br />