02.99 05.03<br />

n-set mode<br />

STW<br />

ZSW<br />

Control word<br />

Status word<br />

START<br />

p Bit dep. on the program (0 or 1)<br />

s Traversing task bit of the STW<br />

x Bit not defined (0 or 1)<br />

Change from 0 to 1 or 1 to 0<br />

Change from 0 to 1 and back again<br />

Change from 1 to 0 and back again<br />

Voltage<br />

ON<br />

Not ready to<br />

1) this is only valid if STW.5 = 0<br />

power–up<br />

(the speed actual value is kept ZSW =<br />

constant)<br />

x00x x111 x000 x000<br />

Speed,<br />

constant<br />

i.e. STW.5 = 0<br />

Braking down to zero<br />

speed along a ramp<br />

ZSW =<br />

xxxx xxxx x0x1 1111<br />

Braking,<br />

i.e.<br />

STW.4 = 0<br />

Braking with maximum<br />

acceleration<br />

ZSW =<br />

xxxx xxxx x0x0 1111<br />

Speed,<br />

constant,<br />

i.e. STW.5 = 0<br />

Enable<br />

setpoint,<br />

i.e. STW.6 = 1<br />

Setpoint<br />

inhibit<br />

i.e. STW.6 = 0<br />

Speed<br />

increases,<br />

i.e. STW.5 = 1<br />

STW.6 = 1 1)<br />

STW.6 = 0 1)<br />

Inhibit setpoint<br />

i.e. STW.6 = 0<br />

Enable setpoint<br />

i.e. STW.6 = 1<br />

Initializing<br />

i.e.<br />

STW = xxxx xxxx x000 1111<br />

Operation enabled<br />

ZSW =<br />

1x0x xxxx x000 1111<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

Power–on inhibit<br />

ZSW<br />

x00x x111 x111 0000<br />

Speed setpoint is accepted<br />

i.e. STW.4/5/6 = 1 (any<br />

sequence)<br />

Ramp–up to the<br />

setpoint<br />

ZSW =<br />

xxxx xxxx x111 1111<br />

Constant speed,<br />

i.e. STW.5 = 0<br />

Speed actual value is<br />

kept constant<br />

ZSW =<br />

xxxx xxxx x101 1111<br />

Braking,<br />

i.e. STW.4 =0<br />

Braking with maximum<br />

acceleration<br />

ZSW =<br />

xxxx xxxx x1x0 1111<br />

Speed<br />

constant,<br />

i.e. STW.5 = 0<br />

Fig. 4-6 Flow diagram, ”Variable–speed drives” for the n-set mode<br />

4 Communications via PROFIBUS DP<br />

OFF 1<br />

i.e.<br />

STW.0 =<br />

Braking,<br />

i.e.<br />

STW.4 = 0<br />

4.2 Process data (PZD area)<br />

OFF 2<br />

i.e. STW.1 = 0<br />

(from each<br />

device status)<br />

OFF 2 active<br />

ZSW =<br />

xxxx xxxx x1x0 x000<br />

No OFF 2<br />

i.e. STW.1 = 1<br />

OFF 3<br />

i.e. STW.2 = 0<br />

(from any<br />

device status)<br />

OFF 3 active<br />

ZSW =<br />

xxxx xxxx x10x x000<br />

No OFF 3<br />

i.e. STW.2 = 1<br />

Fault<br />

(from any<br />

device status)<br />

Fault<br />

ZSW =<br />

xxxx xxxx xxxx 1xxx<br />

Fault resolved,<br />

acknowledge faults<br />

i.e. STW.7 =<br />

4-109<br />