5 Description of the Functions 02.99 04.01<br />

5.5 SIMODRIVE POSMO A functions<br />

Jogging<br />

in the standalone<br />

mode<br />

Parameters<br />

(refer to Chapter<br />

5.6.2)<br />

5-170<br />

Assumption:<br />

Jogging 1 and 2 are permanently connected via digital inputs and parameterized<br />

using P31 and P32 (refer to Chapter 5.5.10).<br />

This means that when the bus communications fail, in order that the<br />

positioning motor can still be jogged via these inputs, the following applies:<br />

Before SW 1.3 the following applies:<br />

In order to be able to jog, only one block without traversing motion<br />

may be entered in P101:1.<br />

e.g.: P101:1 = 5, P101:2 – :10 = 0, block 5 with standard values<br />

The following applies from SW 1.3:<br />

In order to be able to jog, P101:1 – :10 = 0 or 0.<br />

If a block sequence is specified in P101:10, then a jogging signal<br />

which is present is always effective before repeating the last specified<br />

block.<br />

e.g.: P101:1 = 5, P101:2 = 7 and P101:3 – :10 = 0<br />

––> jogging is effective before repeating block 7<br />

P100 control word simulation<br />

P101:11 block sequence in the standalone mode<br />

Siemens AG <strong>2003</strong> All rights reserved<br />