2<br />

2 Installing and Connecting–up 02.99<br />

2.2 Electrical system requirements<br />

Withdrawing/<br />

inserting the<br />

connection cover<br />

under voltage<br />

i 2 t limiting<br />

2-32<br />

The connection cover can be withdrawn and inserted under voltage<br />

with the motor stationary (OFF 1).<br />

If the PROFIBUS terminating resistor is not switched in on this node,<br />

i.e. if this drive is not the first or last node, then communications to the<br />

other bus nodes is not interrupted.<br />

Notice<br />

When the connection is withdrawn, the actual position is not saved.<br />

This means that the drive must be re–referenced after the cover has<br />

been inserted.<br />

This limiting function protects the positioning motor against permanent<br />

overload.<br />

If the positioning motor is operated for an excessive time over the<br />

permissible load limit, then the available motor current is automatically<br />

limited according to a characteristic.<br />

I [A]<br />

9<br />

4.5<br />

0<br />

15<br />

Warning<br />

801 / P953.1 (refer to Chapter 6.2.2)<br />

Fig. 2-7 i 2 t characteristic for the 75 W motor<br />

21<br />

10.5<br />

I [A]<br />

20<br />

15<br />

10<br />

5<br />

0<br />

15<br />

Warning<br />

801 / P953.1 (refer to Chapter 6.2.2)<br />

60<br />

Fig. 2-8 i 2 t characteristic for the 300 W motor<br />

not to scale<br />

t [s]<br />

not to scale<br />

Warning<br />

801 / P953.1 (refer to Chapter 6.2.2)<br />

t [s]<br />

Siemens AG <strong>2003</strong> All rights reserved<br />