04.01<br />

Traversing<br />

possibilities<br />

(examples)<br />

Traversing blocks<br />

and programs<br />

Communications<br />

Diagnostics<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

1.1 General information about SIMODRIVE POSMO A<br />

The positioning motor can be traversed as follows:<br />

Traverse to an end position with a velocity and acceleration which<br />

can be overridden.<br />

Traverse through a distance in a direction with velocity and acceleration<br />

which can be overridden.<br />

Traverse with a speed and acceleration which can be overridden,<br />

direction is defined by the sign, as long as a time of logic condition<br />

is fulfilled.<br />

Traverse as soon as an additional time or logic condition is fulfilled.<br />

Traverse as long as a time or logic condition is fulfilled.<br />

There are a total of 27 traversing blocks, which can be used as individual<br />

blocks or as program.<br />

The traversing blocks are subdivided as follows:<br />

Trav. block Use<br />

1 and 2 Reserved for jogging<br />

3 – 12 Individual traversing blocks<br />

13 – 17 Program 1 (standard, can be freely parameterized)<br />

18 – 22 Program 2 (standard, can be freely parameterized)<br />

23 – 27 Program 3 (standard, can be freely parameterized)<br />

This setting is used as standard. Blocks 3 to 27 can be freely used as<br />

single blocks or programs.<br />

The PROFIBUS–DP fieldbus allows fast, cyclic data transfer between<br />

the individual DP slaves and the higher–level DP master.<br />

DP masters include, for example:<br />

Central controller of SIMATIC S7<br />

Master–capable communication processes (e.g. CP 5613)<br />

Communications modules (e.g. CP 342–5)<br />

Standard masters from other manufacturers<br />

Reference: /IKPI/ Industrial Communications and<br />

Field Devices, Catalog<br />

Local diagnostics using LEDs for Fault/Ready.<br />

1 Brief Description<br />

The DP master can read–out and evaluate positioning motor faults and<br />

warnings via PROFIBUS.<br />

Two freely parameterizable analog test outputs for measurements<br />

when service is required.<br />