SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

2.4 Mounting SIMODRIVE POSMO A<br />

2.4.3 Mounting the prepared cables in the connection cover<br />

How are the<br />

prepared cables<br />

installed?<br />

The following sequence should be maintained when installing the prepared<br />

cables into the connection cover (refer to Fig. 2-23):<br />

1. Release the nut, dummy plugs and terminal insert/seal from the PG<br />

gland.<br />

2. Locate the nut and clamping insert/seal onto the cable.<br />

3. Open–up the shield braiding (remove the insulating foil below).<br />

The shield must cover the O ring by approx. 2 mm.<br />

Cleanly cut–off excessive shield!<br />

4. Assemble the nut with clamping insert/seal.<br />

5. Insert these into the PG gland and tighten the nut.<br />

6. Connect the ends of the cables to the lower side of the connection<br />

cover.<br />

Point 1<br />

Nut<br />

Point 2<br />

Point 3<br />

Point 3<br />

Point 4<br />

Point 5<br />

Ó<br />

Ó<br />

Dummy plugs<br />

Ó<br />

Ó<br />

Ó<br />

Clamping insert/seal<br />

Connection to the PROFIBUS unit<br />

Ó<br />

ÓÓ<br />

ÓÓ<br />

ÓÓ<br />

ÓÓ<br />

Fig. 2-23 How are the prepared cables installed?<br />

2 Installing and Connecting–up<br />

O ring<br />

M20 gland<br />

Shield<br />

M20 gland<br />

Point 6<br />

Wiring at<br />

X20<br />

2-49<br />