2 Installing and Connecting–up 02.99 <strong>08</strong>.03<br />

2.2 Electrical system requirements<br />

2.2 Electrical system requirements<br />

2.2.1 General electrical requirements<br />

General<br />

requirements<br />

2-26<br />

The following general requirements must be observed:<br />

The PROFIBUS–DP is coupled in conformance with the Standard.<br />

A standard PROFIBUS cable can be used. In order to loop in the<br />

optional electronics power supply, the same bus cable can be used<br />

that is used in the distributed ET 200X I/O device.<br />

References: /ET200X/ Distributed ET 200X I/O<br />

All of the bus nodes should be certified for PROFIBUS use.<br />

Note<br />

When using connector couplings for PROFIBUS, at higher data<br />

transfer rates (> 1.5 Mbaud), perfect functioning is no longer<br />

guaranteed (cable reflection).<br />

An external power supply is required (24 V for a 75 W motor and<br />

48 V for a 300 W motor, refer to Chapter 2.6.1 or 2.6.2 for technical<br />

data).<br />

The maximum conductor cross–section for the load power supply is<br />

4 mm2 . If the power supply which is used, can supply more current<br />

than is permissible for the particular cable, then appropriate fuses<br />

must be provided.<br />

A Power Management Module (DC-PMM) can be optionally connected<br />

between the external load power supply and input terminals of<br />

SIMODRIVE POSMO A. The DC-PMM is used to dissipate any regenerative<br />

feedback energy and to limit cable–borne disturbances.<br />

If the bus communications and position sensing are to remain active<br />

even with the load power supply switched–out, then an optional<br />

electronics power supply (24 V 20 %) can be used. The cables<br />

are routed in the ET 200X bus cable (distributed peripheral system).<br />

A BERO can only be connected as type 3–wire PNP.<br />

The grounding concept is specified corresponding to the data provided<br />

in Chapter 2.3.<br />

The signal and power cables should be routed with a minimum<br />

20 cm clearance between them and as close as possible to grounded<br />

parts.<br />

When using a contactor in the load power supply, before opening<br />

the contactor, it must be ensured that the pulses have been canceled<br />

via PROFIBUS (OFF 1).<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong>