02.99 04.01 <strong>08</strong>.03<br />

P0016 / 10 Max. overcurrent<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

5 Description of the Functions<br />

5.6 Parameters for SIMODRIVE POSMO A<br />

300W<br />

Min Standard Max Unit Data type Effective<br />

0 10.5 42 A C4 immed.<br />

Max. overcurrent for the breakaway torque.<br />

Note:<br />

This parameter has a gearbox-dependent factory default.<br />

The parameter is valid for: n < 100 RPM and max. 500 ms<br />

The parameter value can be changed while traversing.<br />

075W<br />

Min Standard Max Unit Data type Effective<br />

0 9 18 A C4 immed.<br />

Max. overcurrent for the breakaway torque.<br />

Note:<br />

This parameter has a gearbox-dependent factory default.<br />

The parameter is valid for: n < 100 RPM and max. 500 ms<br />

The following applies as from SW 1.5:<br />

The parameter value can be changed while traversing.<br />

P0017 / 11 P gain, speed controller<br />

300W<br />

Min Standard Max Unit Data type Effective<br />

0 3 100 – I4 immed.<br />

The parameter specifies the P gain for traversing operation.<br />

Note:<br />

The parameter value can be changed while traversing.<br />

Also refer to P54<br />

075W<br />

Min Standard Max Unit Data type Effective<br />

0 20 100 – I4 immed.<br />

The parameter specifies the P gain for traversing operation.<br />

Note:<br />

The parameter value can be changed while traversing.<br />

The following applies before SW 1.2: Max. value = 40<br />

Also refer to P54<br />

P0018 / 12<br />

300W<br />

Integral action time, speed controller<br />

Min Standard Max Unit Data type Effective<br />

2 10 1000 ms T2 immed.<br />

The parameter specifies the I component for the speed controller.<br />

Note:<br />

The parameter value can be changed while traversing.<br />

075W<br />

Min Standard Max Unit Data type Effective<br />

2 22 1000 ms T2 immed.<br />

The parameter specifies the I component for the speed controller.<br />

Note:<br />

The parameter value can be changed while traversing.<br />

5-189<br />

5