02.99 04.01<br />

5.6.2 List of parameters<br />

Explanation of the<br />

parameter list<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

5.6 Parameters for SIMODRIVE POSMO A<br />

Reader’s note<br />

The parameters, listed in the following, are valid for all software<br />

releases of SIMODRIVE POSMO A.<br />

The complete list is updated corresponding to the <strong>Edition</strong> of the<br />

documentation (refer to the <strong>Edition</strong> status in the header line) and<br />

corresponds to the software release of SIMODRIVE POSMO A<br />

documented here.<br />

The parameters that are dependent on the software release are<br />

appropriately identified.<br />

The parameters are shown in the parameter list as follows:<br />

Parameter number (examples)<br />

P0010 Parameter 10 without index<br />

P0<strong>08</strong>2:28 Parameter 82 with index 0, 1, ... 27 (28 indices)<br />

P0<strong>08</strong>2:13 Parameter 82 with index 13<br />

P0<strong>08</strong>2:x Parameter 82 with undefined index x<br />

P0056.2 Parameter 56 bit 2<br />

decimal hexadecimal<br />

Pdddd || hh word_word word_word<br />

075W 300W<br />

Min Standard Max Units Data type Effective<br />

xx xx xx xx yy zz<br />

Parameter description<br />

Motor type<br />

Specifies for which motor the parameter is<br />

valid.<br />

075W ––> 75 W motor<br />

300W ––> 300 W motor<br />

Units<br />

MSR: Measuring system grid<br />

1 MSR = 1 mm for P4 = 0<br />

1 MSR = 1 degr. for P4 = 1<br />

1 MSR = 1 inch for P4 = 2<br />

Fig. 5-20 Parameter list<br />

Parameter text<br />

5 Description of the Functions<br />

Data type<br />

––> Refer to Chapter 4.3.1<br />

Effective<br />

immediately ––> becomes immediately<br />

effective when a change is made<br />

When a parameter is changed, the motor must<br />

always be stationary. If a parameter can be changed<br />

while the axis is traversing, then an explicit reference<br />

is made.<br />

RO ––> Read Only<br />

The parameter can only be read and not written into.<br />