5.6 Parameters for SIMODRIVE POSMO A<br />
300W 075W<br />
Min Standard Max Unit Data type Effective<br />
– – – – I2 RO<br />
All of the parameters supported by the device are listed here in an increasing sequence.<br />
P980:0 ––> no significance<br />
P980:1 = 1 (P1)<br />
...<br />
P980:77 = 990 (P990)<br />
P0990:78 / 3DE Changes with respect to the factory default<br />
300W 075W<br />
Min Standard Max Unit Data type Effective<br />
– – – – I2 RO<br />
All of the parameters which have been changed over the factory default are listed here in an<br />
increasing sequence.<br />
P990:0 ––> no significance<br />
P990:1 = 4 (e.g. P4)<br />
P990:2 = 990 (P990)<br />
P990:3 = after the end of the list<br />
Note:<br />
For parameters with index, the parameter number is listed if at least 1 parameter of the array<br />
was changed.<br />
P1426 / 592 Tolerance band for actual setpoint value<br />
5 Description of the Functions<br />
300W<br />
Min Standard Max Unit Data type Effective<br />
0<br />
075W<br />
100 3800 rpm C4 immed.<br />
Min Standard Max Unit Data type Effective<br />
0<br />
”<br />
100 3600 rpm C4 immed.<br />
This parameter defines the tolerance band for the actual speed value.<br />
If the actual speed value is within this tolerance band around the specified setpoint, the bit<br />
”Speed within tolerance band” is output (ZSW.8).<br />
Note:<br />
This parameter is visible in SimoCom A only in operating mode ”Speed setpoint” (P930).<br />
Available with software version 2.0 and higher.<br />
P1427 / 593 Delay time Nsetpoint has elapsed<br />
300W 075W<br />
Min Standard Max Unit Data type Effective<br />
0 0 15000 ms T2 immed.<br />
This parameter defines the delay time following which the bit ”Ramp-up complete” (ZSW.10) is<br />
output.<br />
If the actual speed value for the specified time is within the tolerance band (P1426), ZSW.10 is<br />
output.<br />
Note:<br />
This parameter is visible in SimoCom A only in operating mode ”Speed setpoint” (P930).<br />
Available with software version 2.0 and higher.<br />