Table 4-15 Error IDs for the ”DP slave POSMO A”<br />

Data types<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

4.3 Parameter area (PKW area)<br />

Error ID Error cause<br />

0 Illegal parameter number (the parameter does not exist)<br />

1 Parameter value cannot be changed (the parameter can only be read or is write<br />

protected)<br />

2 Upper or lower value limit exceeded<br />

3 Incorrect sub–index<br />

4 No array (parameter does not have any sub–parameter)<br />

5 Incorrect data type<br />

9 Descriptive element not available<br />

17 Task cannot be executed due to the operating state<br />

18 Other error<br />

Table 4-16 Parameter formats<br />

Format Length<br />

(Byte)<br />

The data type, to which the parameter is assigned, must be written into<br />

the parameter values using the PKW mechanism.<br />

The following apply for the format names (acc. to the recommended<br />

PROFIBUS guideline):<br />

Description<br />

C4 4 Fixed–point value, 32 bit with 4 decimal places (value = number / 10 000)<br />

Example:<br />

P11 = 75 000 ––> 7.5 mm<br />

I4 4 32–bit integer number (32–bit integer)<br />

I2 2 16–bit integer number (16–bit integer)<br />

T4 4 32–bit time constant (as for unsigned 32–bit integer)<br />

Time as a multiple of the sampling time of 10 ms<br />

T2 2 16–bit time constant (as for unsigned 16–bit integer)<br />

Time is entered as a multiple of the sampling time<br />

Speed control = 1 ms, position control = 10 ms<br />

N2 2 Linear normalized value 200 %: 100 % 4 000 hex (16 384 dec)<br />

E2 2 Linear fixed–point value, 16 bit with 7 binary decimal places<br />

0 0hex, 128 4 000hex 2 V 2 Bit sequence<br />

16 Boolean quantities combined in 2 octets<br />

4 Communications via PROFIBUS DP<br />

Note<br />

All data are saved in the little Endian format (the same as for the<br />

PROFIBUS Standard).<br />