04.01 <strong>08</strong>.01<br />

!<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

1 Brief Description<br />

1.3 Safety–related information<br />

Caution<br />

11.Suitable equipment must be used when mounting withdrawing<br />

drive–out elements (e.g. coupling disk, belt pulley, gear, ...).<br />

12.The motor may not be used as a step.<br />

13.The valid national, local and plant/system–specific regulations and<br />

requirements must be carefully observed.<br />

Caution<br />

14.It is not permissible to connect the unit to the three–phase line<br />

supply as this could destroy the unit.<br />

15.When mounting SIMODRIVE POSMO A with the shaft end facing<br />

upwards, it must be guaranteed that no liquid can penetrate into the<br />

upper bearing.<br />

16.Ensure that the unit is correctly mounted at its flange and is<br />

precisely aligned. If increased noise/vibration/temperatures occur, if<br />

in doubt, power down.<br />

17.If large amounts of dirt accumulate, the air ducts should be<br />

regularly cleaned.<br />

18.Axial forces are not permissible for SIMODRIVE POSMO A –<br />

300 W with integrated holding brake.<br />

After the motor has been mounted, the brake should be checked to<br />

ensure that it functions perfectly.<br />

The brake is only designed for a limited number of emergency<br />

braking operations. It is not permissible to use the brake as<br />

operating brake.<br />

19.Supporting SIMODRIVE POSMO A 300 W<br />

If the motor is subject to extreme vibration/shock loads, then it must<br />

be supported using the three M5 threaded holes and an appropriate<br />

bracket.<br />

20.Degree of protection<br />

It is not permissible that foreign bodies, dirt or moisture accumulate<br />

at the connections.<br />

Cable entry glands that are not used must be sealed so that they<br />

are dust–tight and watertight!<br />

In order to guarantee the degree of protection, all of the<br />

connections must be sealed using plugs or with an appropriate PG<br />

gland.<br />

21.When mounting and withdrawing drive–out elements at the output<br />

shaft, it is neither permissible to apply heavy knocks (e.g. using a<br />

hammer) to the shaft end nor exceed the maximum permissible<br />

axial or radial load at the shaft end.<br />

22.The motors must be stored under the following ambient conditions:<br />

Dry, dust–free and low vibration levels (vrms 0.2 mm/s)<br />