Table 3-1 Information on ”SimoCom A”, continued<br />
Siemens AG <strong>2003</strong> All rights reserved<br />
SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />
3.2 Commissioning the DP master<br />
Function Description<br />
Working offline ... this means that you are only working at the computer and you do not have a<br />
connection to a drive. Only the opened files are included in the browser under<br />
”Operate”.<br />
Working online ... this means that you are connected with one or several drives and ”SimoCom<br />
A” also recognizes these drives.<br />
This is the case if ”SimoCom A” has already searched for the interface once.<br />
You go online, if<br />
Your default is set in the menu ”Options/Settings/Communications” (this is<br />
realized when starting ”SimoComA”)<br />
You make the selection with the operator action ”Search for online drives”<br />
In the online mode, the opened files and all of the drives available via the<br />
interface are contained in the browser under ”Operate”.<br />
Note:<br />
The parameters displayed via ”SimoCom A” are not cyclically read.<br />
Working in the drive You can work directly in the drive or only at the PC in the file, but only with one<br />
or<br />
data set at any one time.<br />
in the file<br />
For example, you can be connected with a POSMO A – 300 W (4A) and a<br />
POSMO A – 75 W (6A), so that you have access to the parameter sets in both<br />
of the drives – and at the same time have several files open. All of these<br />
parameter sets are displayed in the browser under ”Operate” and also in the<br />
menu ”File”.<br />
If you select ”Drive 4A”, then you will see the current status and parameters of<br />
drive 4A – but no others. When changing over, for example to the ”My.par” file,<br />
then you only see the parameters associated with this file.<br />
Parameters files which have been opened can be re–closed using<br />
the”File/Close file” menu.<br />
Assign the PC the<br />
control priority<br />
Returning the control<br />
authority<br />
Procedure when commissioning<br />
... means that the ”DP slave POSMO A” should be controlled from the PC.<br />
How is the control authority transferred to the PC?<br />
The C1 master must signal OFF 1, OFF 2 or OFF 3<br />
Transfer the control authority to the PC using the menu ”Operator control/<br />
control authority for PC”<br />
... means that the ”DP slave POSMO A” should be controlled from the C1<br />
master.<br />
How is the control authority returned?<br />
Bring the drive to a standstill<br />
Withdraw the PC controller enable<br />
Recommendation: Set the browser to ”Parameter” and work through the<br />
following dialog boxes one after the other ”Configuration – re–configure drive”<br />
––> ”Mechanical system” ––> ”Traversing blocks”.<br />
1. Configuration ... here, enter the drive type being used, the gearbox stage and the braking<br />
option (this only applies to the 300 W motor).<br />
If this data is changed, this causes the parameters, which are dependent on it,<br />
to be re–calculated, i.e. changes previously made to the parameters involved<br />
are overwritten.<br />
2. Mechanical system ... here, you can define the mechanical system used<br />
(e.g. rotary axis?, external gearbox?).<br />
3 Start–up<br />
3-75<br />
3