Table 3-1 Information on ”SimoCom A”, continued<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

3.2 Commissioning the DP master<br />

Function Description<br />

Working offline ... this means that you are only working at the computer and you do not have a<br />

connection to a drive. Only the opened files are included in the browser under<br />

”Operate”.<br />

Working online ... this means that you are connected with one or several drives and ”SimoCom<br />

A” also recognizes these drives.<br />

This is the case if ”SimoCom A” has already searched for the interface once.<br />

You go online, if<br />

Your default is set in the menu ”Options/Settings/Communications” (this is<br />

realized when starting ”SimoComA”)<br />

You make the selection with the operator action ”Search for online drives”<br />

In the online mode, the opened files and all of the drives available via the<br />

interface are contained in the browser under ”Operate”.<br />

Note:<br />

The parameters displayed via ”SimoCom A” are not cyclically read.<br />

Working in the drive You can work directly in the drive or only at the PC in the file, but only with one<br />

or<br />

data set at any one time.<br />

in the file<br />

For example, you can be connected with a POSMO A – 300 W (4A) and a<br />

POSMO A – 75 W (6A), so that you have access to the parameter sets in both<br />

of the drives – and at the same time have several files open. All of these<br />

parameter sets are displayed in the browser under ”Operate” and also in the<br />

menu ”File”.<br />

If you select ”Drive 4A”, then you will see the current status and parameters of<br />

drive 4A – but no others. When changing over, for example to the ”My.par” file,<br />

then you only see the parameters associated with this file.<br />

Parameters files which have been opened can be re–closed using<br />

the”File/Close file” menu.<br />

Assign the PC the<br />

control priority<br />

Returning the control<br />

authority<br />

Procedure when commissioning<br />

... means that the ”DP slave POSMO A” should be controlled from the PC.<br />

How is the control authority transferred to the PC?<br />

The C1 master must signal OFF 1, OFF 2 or OFF 3<br />

Transfer the control authority to the PC using the menu ”Operator control/<br />

control authority for PC”<br />

... means that the ”DP slave POSMO A” should be controlled from the C1<br />

master.<br />

How is the control authority returned?<br />

Bring the drive to a standstill<br />

Withdraw the PC controller enable<br />

Recommendation: Set the browser to ”Parameter” and work through the<br />

following dialog boxes one after the other ”Configuration – re–configure drive”<br />

––> ”Mechanical system” ––> ”Traversing blocks”.<br />

1. Configuration ... here, enter the drive type being used, the gearbox stage and the braking<br />

option (this only applies to the 300 W motor).<br />

If this data is changed, this causes the parameters, which are dependent on it,<br />

to be re–calculated, i.e. changes previously made to the parameters involved<br />

are overwritten.<br />

2. Mechanical system ... here, you can define the mechanical system used<br />

(e.g. rotary axis?, external gearbox?).<br />

3 Start–up<br />

3-75<br />

3