6 Fault Handling and Diagnostics 02.99 <strong>08</strong>.03<br />
6.2 Faults and warnings<br />
803 / P953.3 Software limit switch, start<br />
Cause The actual position lies outside the range defined by the software limit<br />
switch.<br />
When traversing to a software limit switch, the motor is always stopped.<br />
SW 1.6 and higher: This warning is also signalled if the traversing range<br />
limits of the axis (+/– 200000mm or degrees or inches) are reached. In<br />
this case, the additional information 910 (P954.10) is output.<br />
SW 2.0 and higher: This warning is also output when the corresponding<br />
hardware limit switch (start) has been overrun.<br />
In this case, additional information 911 (P954.11) is output.<br />
Note:<br />
The warning is only signaled if the appropriate fault is suppressed.<br />
Remedy Move away in the opposite direction.<br />
Check P6 (software limit switch, start).<br />
Acknowledgement not required<br />
Stop response None<br />
804 / P953.4 Software limit switch, end<br />
Cause The actual position lies outside the range defined by the software limit<br />
switch.<br />
When traversing to a software limit switch, the motor is always stopped.<br />
SW 1.6 and higher: This warning is also signalled if the traversing range<br />
limits of the axis (+/– 200000mm or degrees or inches) are reached. In<br />
this case, the additional information 910 (P954.10) is output.<br />
SW 2.0 and higher: This warning is also output when the corresponding<br />
hardware limit switch (end) has been overrun.<br />
In this case, additional information 911 (P954.11) is output.<br />
Note:<br />
The warning is only signaled if the appropriate fault is suppressed.<br />
Remedy Move away in the opposite direction.<br />
Check P7 (software limit switch, end).<br />
Acknowledgement not required<br />
Stop response None<br />
805 / P953.5 Jogging: Jogging not possible<br />
Cause Drive not enabled.<br />
Jogging already selected.<br />
Traversing block being processed.<br />
Note:<br />
Additional information? ––> evaluate P954<br />
Remedy –<br />
Acknowledgement not required<br />
Stop response None<br />