6 Fault Handling and Diagnostics 02.99 <strong>08</strong>.03<br />

6.2 Faults and warnings<br />

803 / P953.3 Software limit switch, start<br />

Cause The actual position lies outside the range defined by the software limit<br />

switch.<br />

When traversing to a software limit switch, the motor is always stopped.<br />

SW 1.6 and higher: This warning is also signalled if the traversing range<br />

limits of the axis (+/– 200000mm or degrees or inches) are reached. In<br />

this case, the additional information 910 (P954.10) is output.<br />

SW 2.0 and higher: This warning is also output when the corresponding<br />

hardware limit switch (start) has been overrun.<br />

In this case, additional information 911 (P954.11) is output.<br />

Note:<br />

The warning is only signaled if the appropriate fault is suppressed.<br />

Remedy Move away in the opposite direction.<br />

Check P6 (software limit switch, start).<br />

Acknowledgement not required<br />

Stop response None<br />

804 / P953.4 Software limit switch, end<br />

Cause The actual position lies outside the range defined by the software limit<br />

switch.<br />

When traversing to a software limit switch, the motor is always stopped.<br />

SW 1.6 and higher: This warning is also signalled if the traversing range<br />

limits of the axis (+/– 200000mm or degrees or inches) are reached. In<br />

this case, the additional information 910 (P954.10) is output.<br />

SW 2.0 and higher: This warning is also output when the corresponding<br />

hardware limit switch (end) has been overrun.<br />

In this case, additional information 911 (P954.11) is output.<br />

Note:<br />

The warning is only signaled if the appropriate fault is suppressed.<br />

Remedy Move away in the opposite direction.<br />

Check P7 (software limit switch, end).<br />

Acknowledgement not required<br />

Stop response None<br />

805 / P953.5 Jogging: Jogging not possible<br />

Cause Drive not enabled.<br />

Jogging already selected.<br />

Traversing block being processed.<br />

Note:<br />

Additional information? ––> evaluate P954<br />

Remedy –<br />

Acknowledgement not required<br />

Stop response None<br />

6-222<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong>