2<br />

2 Installing and Connecting–up 02.99<br />

2.2 Electrical system requirements<br />

2-30<br />

Our second recommendation for the 48 V power supply:<br />

Use two SITOP power regulated power supply modules connected in<br />

series to provide the 48 V load power supply.<br />

There are units with current ratings of 10 A, 20 A and 40 A.<br />

L+<br />

SITOP power<br />

M<br />

L+<br />

SITOP power<br />

M<br />

24 V<br />

24 V<br />

Note:<br />

V x Protective diode (blocking voltage: 40 V, current: 3 A)<br />

e.g.: Type SB 540 from RS components Spoerle<br />

Order No.: 183-4337<br />

When connected in series, the SITOP power must have the<br />

same current ratings.<br />

V 1<br />

V 2<br />

Regenerative<br />

feedback<br />

protection<br />

(e.g.<br />

DC-PMM)<br />

48 V<br />

Fig. 2-6 Two SITOP power connected in series to double the voltage<br />

Reference: /KT101/ SITOP power, power supplies<br />

Catalog<br />

Regenerative feedback protection when braking the motor<br />

refer to Chapter 2.2.3<br />

Our third recommendation for the 48 V power supply:<br />

Use a rectifier unit to generate the 48 V load power supply.<br />

The rectifier unit is an uncontrolled DC power supply with safety transformer<br />

and varistor circuit.<br />

Order No.: 4AV3596-0EG30-0C<br />

Applicable regulations<br />

– EN 61558, EN 61131-2<br />

– Noise immunity EN 50<strong>08</strong>2-2, noise emission EN 50<strong>08</strong>1-1<br />

– For connection to the public supply/industrial line supplies<br />

suitable according to EN 61000-3-2/-3-3<br />

Installation conditions<br />

– Upright mounting position<br />

– Installation altitude up to 1000 m above sea level<br />

– M6 bolt mounting using a bracket<br />

– Rooms with outdoor climatic conditions according to DIN 50010<br />

– Ambient temperature –25 C to +40 C<br />

– Storage temperature –25 C to +60 C<br />

Siemens AG <strong>2003</strong> All rights reserved<br />