3 Start–up 02.99 05.03<br />

3.2 Commissioning the DP master<br />

Settings for<br />

”SimoCom A”<br />

Example:<br />

Online operation<br />

via PROFIBUS<br />

3-72<br />

PG/PC<br />

For ”SimoCom A”, communications should be set as follows via<br />

PROFIBUS–DP:<br />

Options – Settings – Communications ––> ”Interface” dialog”<br />

With ”For ”Go online” connect via” set the following:<br />

––> ”direct connection”, if the coupling is directly established<br />

or<br />

––> ”routed via S7”, if the coupling is established through the<br />

MPI interface<br />

Online operation can be directly established to the drive directly via the<br />

fieldbus using the ”Go online” function.<br />

Parameterizing<br />

and start–up tool<br />

”SimoCom A”<br />

Setup.exe<br />

MPI<br />

or<br />

CP 5511<br />

or<br />

CP 5611<br />

or<br />

CP 5613<br />

ÄÄ<br />

ÄÄ<br />

SIMATIC S7-300 (CPU: S7-315-2-DP)<br />

PROFIBUS DP<br />

At the last node (in this case at the left) ––> switch in the terminating resistor (refer to<br />

Chapter 2.3.1)<br />

Set the PROFIBUS node address for the slaves (refer to Chapter 2.3.1)<br />

Fig. 3-5 Example for online operation via PROFIBUS: ”SimoCom A” 2 drives<br />

or<br />

First<br />

node<br />

(in this case,<br />

the master)<br />

––><br />

Switch–in<br />

terminating<br />

resistor<br />

Siemens AG <strong>2003</strong> All rights reserved<br />