19.08.2013 Views

User Manual 08/2003 Edition

User Manual 08/2003 Edition

User Manual 08/2003 Edition

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

02.99 05.03<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

4.2 Process data (PZD area)<br />

Table 4-11 Description of the signals in the status word (ZSW) for the n–set mode, continued<br />

Bit Signal name<br />

Signal status, signal description<br />

15<br />

Load power supply available/<br />

load power supply failed<br />

1 Load power supply available<br />

4 Communications via PROFIBUS DP<br />

0 Load power supply failed<br />

This corresponds to the ”undervoltage” fault<br />

Note:<br />

When an undervoltage condition is detected, the appropriate<br />

fault is signaled and ZSW.15 is set to ”0”.<br />

Before SW 1.3 the following applies:<br />

ZSW.15 is set to ”1”, if, when acknowledging the fault,<br />

an undervoltage condition is no longer detected.<br />

The following is valid SW 1.3:<br />

ZSW.15 is set to ”1” if an undervoltage condition is no<br />

longer detected.<br />

The fault itself remains until it is acknowledged.<br />

ZSW.15 indicates the status of the load power supply,<br />

independent of the fault and acknowledgment.<br />