User Manual 08/2003 Edition
User Manual 08/2003 Edition
User Manual 08/2003 Edition
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
02.99 04.01 <strong>08</strong>.03<br />
P0006 / 06 Software limit switch, start<br />
Siemens AG <strong>2003</strong> All rights reserved<br />
SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />
5 Description of the Functions<br />
5.6 Parameters for SIMODRIVE POSMO A<br />
300W 075W<br />
Min Standard Max Unit Data type Effective<br />
–200000 –200000 200000 MSR C4 immed.<br />
The parameter specifies the software limit switch, left negative.<br />
de-activated: P6 = P7<br />
activated: P6 < P7<br />
Note:<br />
Also refer to P7.<br />
The following applies from SW 2.0:<br />
Software limit switches are not possible in the ”Speed setpoint” operating mode (P930).<br />
P0007 / 07<br />
300W 075W<br />
Software limit switch, end<br />
Min Standard Max Unit Data type Effective<br />
–200000 200000 200000 MSR C4 immed.<br />
The parameter specifies the software limit switch, right positive.<br />
de-activated: P6 = P7<br />
activated:<br />
Note:<br />
P6 < P7<br />
Also refer to P6.<br />
The following applies from SW 2.0:<br />
Software limit switches are not possible in the ”Speed setpoint” operating mode (P930).<br />
P00<strong>08</strong> / <strong>08</strong><br />
300W<br />
Maximum speed<br />
Min Standard Max Unit Data type Effective<br />
0 3000 3800 rpm C4 immed.<br />
Max. motor speed referred to the motor axis<br />
075W<br />
Min Standard Max Unit Data type Effective<br />
0 3000 3600 rpm C4 immed.<br />
Max. motor speed referred to the motor axis.<br />
P0009 / 09<br />
300W 075W<br />
Acceleration time<br />
Min Standard Max Unit Data type Effective<br />
10 100 15000 ms T2 immed.<br />
During this time, in the speed-controlled operation, the setpoint is set as follows:<br />
Ramp-up: From zero up to the maximum permissible actual speed<br />
Ramp-down: From the maximum permissible actual value down to zero<br />
The following applies from SW 2.0:<br />
The ramp-up time can be changed with immediate effect in the ”Speed setpoint” operating mode.<br />
This is also possible when the drive is moving.<br />
P0010 / 0A<br />
300W 075W<br />
Maximum motor velocity<br />
Min Standard Max Unit Data type Effective<br />
0 30000 2000000 MSR/min I4 immed.<br />
Max. permissible velocity, dependent on the system.<br />
The max. speed in P8 was not exceeded in operation.<br />
Note:<br />
This parameter has a gearbox-dependent factory default.<br />
5-187<br />
5