02.99 04.01 <strong>08</strong>.03<br />

P0006 / 06 Software limit switch, start<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

5 Description of the Functions<br />

5.6 Parameters for SIMODRIVE POSMO A<br />

300W 075W<br />

Min Standard Max Unit Data type Effective<br />

–200000 –200000 200000 MSR C4 immed.<br />

The parameter specifies the software limit switch, left negative.<br />

de-activated: P6 = P7<br />

activated: P6 < P7<br />

Note:<br />

Also refer to P7.<br />

The following applies from SW 2.0:<br />

Software limit switches are not possible in the ”Speed setpoint” operating mode (P930).<br />

P0007 / 07<br />

300W 075W<br />

Software limit switch, end<br />

Min Standard Max Unit Data type Effective<br />

–200000 200000 200000 MSR C4 immed.<br />

The parameter specifies the software limit switch, right positive.<br />

de-activated: P6 = P7<br />

activated:<br />

Note:<br />

P6 < P7<br />

Also refer to P6.<br />

The following applies from SW 2.0:<br />

Software limit switches are not possible in the ”Speed setpoint” operating mode (P930).<br />

P00<strong>08</strong> / <strong>08</strong><br />

300W<br />

Maximum speed<br />

Min Standard Max Unit Data type Effective<br />

0 3000 3800 rpm C4 immed.<br />

Max. motor speed referred to the motor axis<br />

075W<br />

Min Standard Max Unit Data type Effective<br />

0 3000 3600 rpm C4 immed.<br />

Max. motor speed referred to the motor axis.<br />

P0009 / 09<br />

300W 075W<br />

Acceleration time<br />

Min Standard Max Unit Data type Effective<br />

10 100 15000 ms T2 immed.<br />

During this time, in the speed-controlled operation, the setpoint is set as follows:<br />

Ramp-up: From zero up to the maximum permissible actual speed<br />

Ramp-down: From the maximum permissible actual value down to zero<br />

The following applies from SW 2.0:<br />

The ramp-up time can be changed with immediate effect in the ”Speed setpoint” operating mode.<br />

This is also possible when the drive is moving.<br />

P0010 / 0A<br />

300W 075W<br />

Maximum motor velocity<br />

Min Standard Max Unit Data type Effective<br />

0 30000 2000000 MSR/min I4 immed.<br />

Max. permissible velocity, dependent on the system.<br />

The max. speed in P8 was not exceeded in operation.<br />

Note:<br />

This parameter has a gearbox-dependent factory default.<br />