Limitations when<br />

referencing<br />

!<br />

Siemens AG <strong>2003</strong> All rights reserved<br />

SIMODRIVE POSMO A <strong>User</strong> <strong>Manual</strong> (POS1) – <strong>08</strong>.03 <strong>Edition</strong><br />

The following limitations apply when referencing:<br />

5 Description of the Functions<br />

5.5 SIMODRIVE POSMO A functions<br />

The positioning motor supplies the following zero marks:<br />

– 75 W motor ––> 4 zero marks per motor revolution<br />

– 300 W motor ––> 1 zero mark per motor revolution<br />

The position of the zero mark, which was last recognized, is overwritten<br />

with the value in P5 (reference point coordinate) by setting<br />

STW.11 (start referencing/stop referencing).<br />

The actual position to be written is corrected by the distance which<br />

was traveled since the last zero mark.<br />

Prerequisite:<br />

The axis must be at a standstill and be in closed–loop control.<br />

If the axis is moving, then the value is not accepted and an alarm is<br />

output.<br />

If the motor was not moved after being powered up, i.e. a zero mark<br />

has still not been passed, and therefore there is no valid position for<br />

a zero mark, then referencing is rejected and a warning output.<br />

The ”referenced” status is lost.<br />

Generally, the following is valid:<br />

ZSW.11 (reference point set/no reference point set) is used to display<br />

whether an axis is referenced.<br />

Resetting the status ”reference point set” (from SW 1.4)<br />

For a stationary axis that has been referenced, the ”no reference<br />

point set” state is re–established by writing a 0 into P98.<br />

The following applies for a non–referenced axis:<br />

– No blocks with absolute position data are executed.<br />

– The axis zero of the axis is the position after the drive has been<br />

powered up.<br />

Warning<br />

For non–referenced axes, the software limit switches are not<br />

monitored.<br />

Suitable measures must be implemented in the system (e.g. hardware<br />

limit switches) in order to avoid injury to personnel and damage to the<br />

machine.<br />