WIPP RH PSAR <strong>DOE</strong>/WIPP-03-3174 CHAPTER 4<br />

4.2.1.1.4 <strong>Waste</strong> Handling Building Effluent Monitoring System<br />

The WHB exhaust system is Design Class IIIA, the supply system is Design Class IIIB, and the HEPA<br />

filters and isolation dampers are Design Class II. The WHB ventilation system has a single discharge<br />

point, with most <strong>of</strong> the air coming from the WHB being processed through a prefilter and two stages <strong>of</strong><br />

HEPA filters prior to its release to the environment. Some <strong>of</strong> the air may go down the waste shaft<br />

(Section 4.4.3.1). Station C is located downstream <strong>of</strong> the HEPA filters and provides fixed air sampling<br />

to quantify the total amount, if any, <strong>of</strong> radioactivity released to the environment.<br />

4.2.1.2 Exhaust Filter Building<br />

The Exhaust Filter Building (EFB), adjacent to the exhaust shaft, contains the HEPA filtration equipment<br />

associated with the underground ventilation system. During normal operations, air is pulled from<br />

underground areas, up the exhaust shaft, and discharged to the environment without the HEPA filtration<br />

units in service. In the event <strong>of</strong> an underground radiological event, airflow from the underground is<br />

diverted through the HEPA filtration to remove airborne radioactive particulates from the air stream. The<br />

underground ventilation system is discussed in Section 4.4.3.3, and the EFB layout is shown in Figure<br />

4.2-30.<br />

The EFB structure is classified as Design Class IIIA, the HEPA filters and isolation dampers are Design<br />

Class II. The major areas within the EFB are the filter room and support area. The filter room houses the<br />

HEPA filtration units. The support area includes two mechanical equipment rooms housing the building<br />

filtration units, the exhaust fans, the supply-air handling units, the motor control centers, and the air lock.<br />

The EFB effluent monitoring system is composed <strong>of</strong> Station A which obtains its sample from a point<br />

21 ft (6.4 m) below ground level in the exhaust shaft and Station B which obtains its sample from a point<br />

downstream from the EFB HEPA filtration system. Each station contains fixed air samplers operated by<br />

the WIPP, one each for WIPP, the Carlsbad Environmental Monitoring and Research Center (CEMRC),<br />

and the Environmental Evaluation Group (EEG), quantifying the total amount <strong>of</strong> radioactivity released to<br />

the environment.<br />

4.2.1.3 Water Pumphouse<br />

The Water Pumphouse, adjacent to the two water storage tanks (Figure 4.1-2a), contains two fire water<br />

pumps (one electric and one diesel), three electric domestic water pumps, and water chlorination<br />

equipment and chemical storage. The Water Pumphouse is an above ground steel frame and siding<br />

building classified as Design Class IIIB.<br />

4.2.1.4 Support Building<br />

The Support Building, adjacent to the WHB, houses general support services for activities at the WIPP<br />

facility. The Support Building is constructed <strong>of</strong> steel framing and sandwich panel siding, and is<br />

classified as Design Class IIIA. The main lateral force-resisting members <strong>of</strong> the Support Building are<br />

designed for DBE and DBT to protect the WHB from their structural failure.<br />