WIPP RH PSAR <strong>DOE</strong>/WIPP-03-3174 APPENDIX C<br />

Table 1- 72B HAZOP Table<br />

Study Node<br />

Event No.<br />

Deviation Causes Consequences Existing Safeguards Actions or<br />

Recommendations<br />

Total Rank<br />

(Cons.,Freq )<br />

Radiological Rank<br />

(Cons.,Freq)<br />

Comments<br />

5 -Road cask transfer to shuttle car<br />

5 - 1 Road cask<br />

dropped in the<br />

cask unloading<br />

room<br />

Human Error;<br />

Equipment<br />

Failure - Crane<br />

Potential for<br />

production<br />

downtime;<br />

Potential for<br />

equipment<br />

damage; Potential<br />

for worker injury<br />

or fatality<br />

Cask/canister design;<br />

Operator training;<br />

<strong>Waste</strong> handling procedures;<br />

Room design limits height <strong>of</strong><br />

lift<br />

R-6 Evaluate the<br />

HVAC (Heating,<br />

Ventilation, and Air<br />

Conditioning) DP’s<br />

(Differential<br />

Pressures) with<br />

road cask<br />

unloading room<br />

door open.<br />

4,4 NA Worker injury or<br />

fatality could<br />

result from the<br />

industrial<br />

accident.<br />

A-5 Verify that<br />

operating<br />

procedures exclude<br />

personnel from<br />

room during cask<br />

transfer for worker<br />

protection<br />

5 - 2 Road cask<br />

dropped into<br />

transfer cell<br />

through the<br />

floor port<br />

Human Error;<br />

Equipment<br />

Failure<br />

(mechanical);<br />

Control Loop<br />

Failure-PLC<br />

(Programmable<br />

Logic Control)<br />

Potential for<br />

production<br />

downtime;<br />

Potential for<br />

equipment<br />

damage;<br />

Potential for<br />

worker injury or<br />

fatality.<br />

Cask/canister design;<br />

Operator training;<br />

<strong>Waste</strong> handling and transfer<br />

cell procedures (entry<br />

restrictions);<br />

Interlocks involving floor<br />

valve, shuttle car, crane<br />

(protects against worker error);<br />

Impact limiter on canister;<br />

Shuttle car design<br />

R-6 Same<br />

Recommendation<br />

as for 5-1:<br />

Evaluate the HVAC<br />

DP’s with road<br />

cask unloading<br />

room door open.<br />

4,4 NA Worker injury or<br />

fatality could<br />

result from the<br />

industrial<br />

accident.<br />

5 - 3 Equipment<br />

performs in<br />

other than<br />

desired mode -<br />

Shield valve<br />

interlocks fail<br />

such that both<br />

shield valves<br />

can be open at<br />

the same time<br />

Equipment<br />

Failure;<br />

Control Loop<br />

Failure-PLC<br />

(Programmable<br />

Logic Control)<br />

Potential for air<br />

flow reversal<br />

(minimal)<br />

Periodic functional checks <strong>of</strong><br />

control loop<br />

NAI NA NA<br />

C-9 January 23, 2003