WIPP RH PSAR <strong>DOE</strong>/WIPP-03-3174 APPENDIX C<br />

Table 2- 10-160B HAZOP Table<br />

Study Node<br />

Event No.<br />

Deviation Causes Consequences Existing Safeguards Actions Total Rank<br />

(Cons., Freq)<br />

Radiological Rank<br />

(Cons.,Freq)<br />

Comments<br />

10BF-1<br />

While lifting<br />

the drum, drop<br />

drum in the Hot<br />

Cell<br />

Human error;<br />

Equipment<br />

failure (sling)<br />

Potential for<br />

onsite and <strong>of</strong>fsite<br />

consequences;<br />

Potential for<br />

spread <strong>of</strong><br />

contamination;<br />

Potential for drum<br />

breach (drop on<br />

top <strong>of</strong> other<br />

drum).<br />

Training and Procedures;<br />

Facility design;<br />

Ventilation systems;<br />

CAMs; Emergency Response<br />

Procedure;<br />

Preventive Maintenance<br />

Program on crane; Crane<br />

design;<br />

Frequent crane inspections;<br />

Shield door closed in the CUR;<br />

Shield plug in Hot Cell is in<br />

place; Shield door crane<br />

interlocks mitigate direct<br />

radiation exposure and/or<br />

spread <strong>of</strong> contamination.<br />

NAI 4,4 Facility Worker -<br />

1,4<br />

Onsite Worker - 4,4<br />

Offsite - 4,4<br />

Radiological<br />

Hazard Only<br />

10C-1 Higher than<br />

expected<br />

contamination<br />

found on swipe<br />

- mishandling<br />

by RCT<br />

Human error;<br />

Equipment<br />

failure<br />

(Glovebox leak)<br />

Potential for<br />

spread <strong>of</strong><br />

contamination;<br />

Potential for<br />

facility worker<br />

exposure.<br />

Training and procedure;<br />

Glove box design;<br />

Inspection <strong>of</strong> gloves;<br />

Preventive Maintenance<br />

Program on Glovebox.<br />

NAI 2,4 Facility Worker -<br />

2,4<br />

Onsite Worker -<br />

NA<br />

Offsite - NA<br />

Radiological<br />

Hazard Only<br />

10D-1 Radiation<br />

exposure<br />

during the<br />

process <strong>of</strong><br />

taking swipes<br />

or glove box<br />

operations<br />

Glovebox<br />

interlock failure<br />

Worker exposure<br />

to Hot Cell via<br />

glovebox.<br />

Interlocks prevent opening<br />

both doors (on Glovebox<br />

drawer) at the same time;<br />

Glovebox design;<br />

Training and procedures;<br />

Glovebox not in normal<br />

streaming path.<br />

NAI 2,4 Facility Worker -<br />

2,4<br />

Onsite Worker -<br />

NA<br />

Offsite - NA<br />

Radiological<br />

Hazard Only<br />

10D-2 Pinch points in<br />

glovebox,<br />

hands in<br />

glovebox,<br />

operator opens<br />

the gallery side<br />

shield plug<br />

Human error;<br />

Maintenance<br />

activity<br />

Potential for<br />

personnel injury.<br />

Pressure pad (Hot<br />

Cell/Glovebox controls)<br />

interlock with shield plug;<br />

Training and procedures;<br />

Preventive Maintenance<br />

Program on Glovebox;<br />

Configuration <strong>of</strong> equipment<br />

controls.<br />

NAI 1,4 NA Industrial<br />

Hazard Only<br />

C-51