WIPP RH PSAR <strong>DOE</strong>/WIPP-03-3174 APPENDIX C<br />

Table 2- 10-160B HAZOP Table<br />

Study Node<br />

Event No.<br />

Deviation Causes Consequences Existing Safeguards Actions Total Rank<br />

(Cons., Freq)<br />

Radiological Rank<br />

(Cons.,Freq)<br />

Comments<br />

5. Unload the Cask in the CUR<br />

5BD-1<br />

Lifting fixture<br />

dropped onto<br />

the drums in<br />

the CUR<br />

Human error;<br />

Equipment<br />

failure<br />

Potential for<br />

breach <strong>of</strong> drums;<br />

Potential for<br />

onsite and<br />

potential for<br />

<strong>of</strong>fsite<br />

consequences;<br />

Potential for<br />

release <strong>of</strong><br />

radiological and<br />

hazardous waste;<br />

Potential to shut<br />

down operations;<br />

Potential for<br />

spread <strong>of</strong><br />

contamination.<br />

Training and Procedures;<br />

Facility design;<br />

Ventilation systems;<br />

CAMs; Emergency Response<br />

Procedure;<br />

Preventive Maintenance<br />

Program on crane; Crane<br />

design;<br />

Fixture design; Frequent crane<br />

inspections; Shield door crane<br />

interlocks mitigate direct<br />

radiation exposure and/or<br />

spread <strong>of</strong> contamination.<br />

NAI 4,4 Facility Worker -<br />

4,4<br />

Onsite Worker - 4,4<br />

Offsite - 4,4<br />

Radiological<br />

Hazard Only<br />

5CE-1<br />

Drum carriage<br />

dropped while<br />

lifting due to<br />

carriage getting<br />

caught and<br />

over stressing<br />

fixture or<br />

basket in the<br />

CUR<br />

Mechanical/<br />

equipment<br />

failure (fixture,<br />

sling, etc);<br />

Human error<br />

Potential for<br />

breach <strong>of</strong> drums;<br />

Potential for<br />

spread <strong>of</strong><br />

contamination;<br />

Potential for<br />

<strong>of</strong>fsite and onsite<br />

consequences;<br />

Potential for<br />

release <strong>of</strong><br />

hazardous waste;<br />

Potential to shut<br />

down operations;<br />

Hot Cell and<br />

unloading room<br />

contaminated.<br />

Fixture design;<br />

Drum carriage design;<br />

Crane design;<br />

Training and Procedures;<br />

Ventilation; Emergency<br />

Response Procedure;<br />

Preventive Maintenance<br />

Program on crane; Frequent<br />

crane<br />

inspections.<br />

NAI 4,4 Facility Worker -<br />

4,4<br />

Onsite Worker - 4,4<br />

Offsite - 4,4<br />

Radiological<br />

Hazard Only<br />

C-41