WIPP RH PSAR <strong>DOE</strong>/WIPP-03-3174 APPENDIX C<br />

Table 2- 10-160B HAZOP Table<br />

Study Node<br />

Event No.<br />

Deviation Causes Consequences Existing Safeguards Actions Total Rank<br />

(Cons., Freq)<br />

Radiological Rank<br />

(Cons.,Freq)<br />

Comments<br />

5CE-2<br />

Drum carriage<br />

dropped inside<br />

the Hot Cell<br />

onto stored<br />

waste<br />

Human error;<br />

Equipment<br />

failure<br />

Potential for<br />

breach <strong>of</strong> canister<br />

and drums;<br />

Potential for<br />

spread <strong>of</strong><br />

contamination;<br />

Potential for<br />

<strong>of</strong>fsite and onsite<br />

consequences;<br />

Potential for<br />

release <strong>of</strong><br />

hazardous waste;<br />

Potential to shut<br />

down operations.<br />

Fixture design;<br />

Drum carriage design;<br />

Crane design;<br />

Training and Procedures;<br />

Ventilation; Emergency<br />

Response Procedure;<br />

Preventive Maintenance<br />

Program on crane; Frequent<br />

crane inspections.<br />

NAI 4,4 Facility Worker -<br />

4,4<br />

Onsite Worker - 4,4<br />

Offsite - 4,4<br />

5CE-3<br />

Broken Hot<br />

Cell window<br />

Human error<br />

(crane, other<br />

equipment<br />

falling into<br />

window);<br />

Equipment<br />

failure;<br />

Nitrogen - over<br />

pressurized<br />

bladders in<br />

window<br />

Potential for loss<br />

<strong>of</strong> shielding to<br />

facility worker;<br />

Potential for<br />

personnel injury<br />

Training and procedures;<br />

Preventive maintenance on<br />

crane and windows (N 2<br />

bladders in windows have<br />

pressure relief valves); Hot<br />

Cell leaded glass on outer<br />

layer<br />

NAI 2,4 Facility Worker -<br />

2,4<br />

Onsite Worker -<br />

NA<br />

Offsite - NA<br />

6. Reinstall Cask Lid in the CUR<br />

6B-1 Cask lid<br />

dropped onto<br />

the cask in the<br />

CUR<br />

Human error;<br />

Equipment<br />

failure<br />

Potential for<br />

facility damage.<br />

Training and Procedures;<br />

Facility design;<br />

Preventive Maintenance<br />

Program on crane; Crane<br />

design; Frequent crane<br />

inspections.<br />

NAI NA NA<br />

6B-2 Cask lid<br />

dropped onto<br />

the stored<br />

waste in the<br />

Hot Cell<br />

Same as event<br />

4H-1<br />

C-42