WIPP RH PSAR <strong>DOE</strong>/WIPP-03-3174 APPENDIX C<br />

Table 1- 72B HAZOP Table<br />

Study Node<br />

Event No.<br />

Deviation Causes Consequences Existing Safeguards Actions or<br />

Recommendations<br />

Total Rank<br />

(Cons.,Freq )<br />

Radiological Rank<br />

(Cons.,Freq)<br />

Comments<br />

13-2 Tornado<br />

(Design Basis<br />

Tornado)<br />

Tornado<br />

Potential for<br />

disruption <strong>of</strong><br />

processing<br />

operations;<br />

Potential to lose<br />

site utilities;<br />

Potential for<br />

worker injury or<br />

fatality;<br />

Potential for fire;<br />

Potential for<br />

explosion<br />

<strong>Waste</strong> Handling Building<br />

designed to withstand<br />

tornados;<br />

Emergency response<br />

procedures;<br />

Recovery Plan;<br />

Weather monitored by CMR<br />

(Central Monitoring Room);<br />

Road cask design - meets DOT<br />

Type B shipping container<br />

certification requirements;<br />

NAI 4,4 NA Worker injury or<br />

fatality could<br />

occur as the<br />

result <strong>of</strong> the<br />

tornado.<br />

13-3 Loss <strong>of</strong> Facility<br />

ventilation<br />

Human Error-<br />

Improper<br />

bulkhead<br />

alignment<br />

Equipment<br />

Failure -Failure<br />

<strong>of</strong> exhaust fans;<br />

Loss <strong>of</strong> electrical<br />

power;<br />

Loss <strong>of</strong><br />

compressed air<br />

Potential to<br />

shutdown<br />

operations<br />

Worker training; Ventilation<br />

system operating procedures;<br />

Preventive Maintenance<br />

Program for ventilation system<br />

equipment;<br />

Redundant Exhaust fans;<br />

Evacuation plan;<br />

Backup diesel generators;<br />

Redundant air compressors<br />

NAI NA NA No release <strong>of</strong><br />

radiological<br />

materials<br />

13-4 Loss <strong>of</strong> power NPH -<br />

Earthquake,<br />

tornado,<br />

lightning, high<br />

winds, etc.;<br />

Vehicle impact;<br />

Power from<br />

commercial<br />

supplier is lost<br />

Potential loss <strong>of</strong><br />

filtered<br />

ventilation;<br />

Potential loss <strong>of</strong><br />

hoist<br />

Backup diesel generators;<br />

Redundant power feeds;<br />

Response procedures; Worker<br />

training<br />

NAI NA NA No release <strong>of</strong><br />

radiological<br />

materials<br />

C-26 January 23, 2003