WIPP RH PSAR <strong>DOE</strong>/WIPP-03-3174 APPENDIX C<br />

Table 1- 72B HAZOP Table<br />

Study Node<br />

Event No.<br />

Deviation Causes Consequences Existing Safeguards Actions or<br />

Recommendations<br />

Total Rank<br />

(Cons.,Freq )<br />

Radiological Rank<br />

(Cons.,Freq)<br />

Comments<br />

8 - 6 Loss <strong>of</strong> brakes<br />

on conveyance<br />

while loaded<br />

with facility<br />

cask -<br />

Conveyance<br />

drops to bottom<br />

<strong>of</strong> waste shaft<br />

Equipment<br />

Failure -Brake<br />

system<br />

Major damage to<br />

shaft;<br />

Potential breach<br />

<strong>of</strong> container;<br />

Potential for<br />

major release <strong>of</strong><br />

radioactive<br />

materials;<br />

Potential for<br />

significant<br />

radiological<br />

exposure to<br />

personnel;<br />

Potential for<br />

considerable<br />

impact <strong>of</strong>fsite;<br />

Potential worker<br />

injury or fatality<br />

Brake system design;<br />

Hoist equipment inspection<br />

program;<br />

Pre-operational checks;<br />

Preventive maintenance<br />

program on hoist including<br />

brake system<br />

NAI 4,4 Facility Worker -<br />

4,4<br />

Onsite Worker - 4,4<br />

Offsite - 4,4<br />

Worker injury or<br />

fatality could<br />

result from the<br />

industrial<br />

accident<br />

(dropped<br />

conveyance with<br />

cask).<br />

Radiological<br />

release would<br />

likely be<br />

extensive<br />

8 - 7 Less than<br />

desired stability<br />

- Facility cask<br />

transfer car not<br />

latched to<br />

conveyance<br />

Human Error<br />

Potential damage<br />

to shaft and<br />

conveyance;<br />

Potential for<br />

process downtime<br />

Operator training; Operating<br />

procedures;<br />

Drive train requires power to<br />

move - (gear driven)<br />

NAI NA NA No release <strong>of</strong><br />

radioactive<br />

material<br />

9 - Facility cask transfer to disposal room<br />

9 - 1 Incorrect<br />

sequence -<br />

Pivot rails not<br />

lowered while<br />

trying to move<br />

Facility cask<br />

transfer car<br />

from<br />

conveyance<br />

Human Error<br />

Potential for<br />

minor damage to<br />

transfer car and<br />

conveyance;<br />

Potential for<br />

minor damage to<br />

pivot rails<br />

Operator Training;<br />

Conveyance operating<br />

procedures<br />

NAI NA NA No release <strong>of</strong><br />

radiological<br />

materials<br />