29.11.2014 Views

DOE 2000. - Waste Isolation Pilot Plant - U.S. Department of Energy

DOE 2000. - Waste Isolation Pilot Plant - U.S. Department of Energy

DOE 2000. - Waste Isolation Pilot Plant - U.S. Department of Energy

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

WIPP RH PSAR <strong>DOE</strong>/WIPP-03-3174 CHAPTER 5<br />

Table 5.1-10 HAZOP Accident Scenario Ranking Page 1 <strong>of</strong> 13<br />

Accident Scenario # Node Deviation Consequence Qualitative<br />

Consequence<br />

Ranking<br />

(Table 5.1-6)<br />

72-B Cask<br />

Qualitative<br />

Frequency<br />

Ranking<br />

(Table 5.1-4)<br />

Prevention/Mitigation<br />

RH1<br />

Fire in the<br />

Underground<br />

9-7 Facility<br />

cask<br />

transfer to<br />

disposal<br />

room<br />

Diesel fire on<br />

forklift<br />

Potential for<br />

significant<br />

radioactive<br />

materials<br />

release<br />

4 4 Prevention: Administrative Controls on<br />

fuel transfer and hot work permit.<br />

Mitigation: Vented canister, Fire<br />

suppression system (on forklift),<br />

Underground ventilation system, Mine<br />

worker training, Mine evacuation plan.<br />

RH1<br />

Fire in the<br />

Underground<br />

10-2<br />

Canister<br />

placement<br />

in borehole<br />

Hydraulic<br />

fluid/diesel<br />

fuel fire<br />

Potential for<br />

significant<br />

radioactive<br />

materials<br />

release<br />

4 4 Prevention: Administrative Controls on<br />

fuel transfer and hot worker permit.<br />

Mitigation: Vented canister, Fire<br />

suppression system (on forklift and<br />

HERE), Underground ventilation<br />

system, Mine worker training, Mine<br />

evacuation plan.<br />

RH2<br />

Fire in the<br />

WHB<br />

7-10 Load<br />

canister into<br />

facility cask<br />

Hydraulic<br />

fluid fire<br />

Potential for<br />

significant<br />

radioactive<br />

materials<br />

release<br />

4 4 Prevention: Administrative Controls on<br />

fuel transfer and hot worker permit.<br />

Mitigation: Limited quantity (app. 40<br />

gallons), Thermal detection alarms,<br />

Sprinkler system, Sump, Evacuation<br />

plan, Emergency exit.<br />

RH3<br />

LOC in the<br />

WHB<br />

7-1 Load<br />

canister into<br />

facility cask<br />

Excessive<br />

movement -<br />

Shuttle moves<br />

while crane is<br />

lifting canister<br />

Potential for<br />

significant<br />

radioactive<br />

materials<br />

release<br />

4 4 Prevention: Program for Shuttle and<br />

control equipment, Pre-op checks, PM<br />

program, Grapple hoist interlock.<br />

Mitigation: Limited access into<br />

Transfer Cell, Building Exhaust HEPA<br />

filtered, Emergency response plan and<br />

teams.<br />

5.1-35 January 22, 2003