WIPP RH PSAR <strong>DOE</strong>/WIPP-03-3174 CHAPTER 8<br />

Beyond vendor and start-up testing, preoperational waste handling demonstration checkouts shall be<br />

conducted using simulated waste. Simulated waste handling operations shall be performed in sequence,<br />

from receipt through final emplacement. The checkouts listed in Table 8.3-1 shall be done according to<br />

the latest approved operating procedures and preoperational checkout demonstration procedures.<br />

Preoperational checkout objectives include:<br />

C<br />

C<br />

C<br />

C<br />

C<br />

Demonstrating that WIPP personnel can safely handle RH TRU waste packages, including unloading<br />

an internally contaminated 72 B or 10-160B cask.<br />

Demonstrating the satisfactory operation <strong>of</strong> WIPP waste handling equipment<br />

Demonstrating that the WIPP operating procedures are comprehensive, and sufficiently detailed to<br />

perform normal waste handling operations, and to recover from <strong>of</strong>f-normal occurrences encountered<br />

during waste handling operations<br />

Establishing the aggregate time estimate for WIPP waste handling operations<br />

Providing the basis for estimating the dose to be received by WIPP waste handling personnel<br />

8.3.4 In-Service Equipment Monitoring Program<br />

8.3.4.1 Conduct <strong>of</strong> Operations<br />

After systems have completed the start-up processes, they are available for day-to-day operations. It is<br />

important to ensure that systems remain within their nominal performance parameters. If systems fail to<br />

operate, repairs are implemented, and operability is re-established.<br />

The Operations <strong>Department</strong> Conduct <strong>of</strong> Operations requires that functional testing be done before<br />

equipment or systems are considered capable <strong>of</strong> performing their design function. The requirement for a<br />

Conduct <strong>of</strong> Operations program is documented in Section 5, Administrative Controls, <strong>of</strong> the TSRs in<br />

Attachment 1.<br />

Responsibility for ongoing evaluation falls with many organizations depending on the nature <strong>of</strong> the<br />

evaluation. For example, some equipment is subjected to periodic operability checks to ensure that<br />

operating parameters are within the range allowed for reliable operations. Examples are environmental<br />

continuous air samplers (covered by WP 02-EM1012, Airborne Particulate Sampling 5 ) and systems<br />

important to safe operation covered by the TSRs in Attachment 1. The following ensure that waste<br />

handling equipment is operating, and operated in a safe manner according to design prior to and during<br />

waste handling activities:<br />

C<br />

C<br />

C<br />

A centralized checklist, maintained by Operations, will be completed prior to entering the <strong>Waste</strong><br />

Handling Mode to meet the requirements <strong>of</strong> TSR Section 1.2.<br />

Periodic oversight <strong>of</strong> the preoperational checks <strong>of</strong> waste handling equipment and facility activities<br />

are conducted by WIPP management.<br />

The WIPP Operations <strong>Department</strong> conducts internal assessments <strong>of</strong> procedural compliance.<br />

8.3-2 January 22, 2003