<strong>ISDN</strong> <strong>ANALYZER</strong> <strong>D1080</strong> USER’S MANUAL REV. 5<br />

If the connection is not ma<strong>de</strong>, the reason is shown in the display<br />

as indicated below.<br />

If the following message is displayed:<br />

124<br />

"Disconnect Layer 1"<br />

check that the bus and the plugs are correctly connected (see<br />

Appendix C) and that the state of the LED’s on the front panel of<br />

the instrument is exact.<br />

In the case of Basic Access and an OUTGOING call, the fixed INFO<br />

1 can indicate that:<br />

− the terminal is not connected to the NT1 termination<br />

− the NT1 is faulty<br />

− the access is not operating<br />

− a terminal on the S-BUS is not connected correctly or<br />

<strong>de</strong>fective<br />

− the connection of the S-BUS is not correct.<br />

In the case of Primary Access, check:<br />

− the CRC4 management of the terminal and the network<br />

− the connections<br />

− the 120Ω balanced line impedance (for connections at 75Ω<br />

unbalanced impedance, the instrument is supplied with<br />

adapter).<br />