<strong>ISDN</strong> <strong>ANALYZER</strong> <strong>D1080</strong> USER’S MANUAL REV. 5<br />
If the connection is not ma<strong>de</strong>, the reason is shown in the display<br />
as indicated below.<br />
If the following message is displayed:<br />
124<br />
"Disconnect Layer 1"<br />
check that the bus and the plugs are correctly connected (see<br />
Appendix C) and that the state of the LED’s on the front panel of<br />
the instrument is exact.<br />
In the case of Basic Access and an OUTGOING call, the fixed INFO<br />
1 can indicate that:<br />
− the terminal is not connected to the NT1 termination<br />
− the NT1 is faulty<br />
− the access is not operating<br />
− a terminal on the S-BUS is not connected correctly or<br />
<strong>de</strong>fective<br />
− the connection of the S-BUS is not correct.<br />
In the case of Primary Access, check:<br />
− the CRC4 management of the terminal and the network<br />
− the connections<br />
− the 120Ω balanced line impedance (for connections at 75Ω<br />
unbalanced impedance, the instrument is supplied with<br />
adapter).<br />
CHAPTER 12. <strong>ISDN</strong> TERMINAL SIMULATOR