USER’S MANUAL REV. 5 <strong>ISDN</strong> <strong>ANALYZER</strong> <strong>D1080</strong><br />

12.2.1. Test configurations<br />

Several test configurations are available, from 64kb bit rate with<br />

only one B channel to 256kb, using four B channels at the same<br />

time in Primary Access.<br />

There are two types of tests: “User-User” and “User-Network”.<br />

The first type features a connection over the whole net section<br />

between two final users, including the routing between the<br />

networks. The second type tests connections between the user<br />

and the corresponding local network.<br />

If the “User-User” test is repeated several times, different results<br />

can be obtained according to the network routing.<br />

The IfTestKo field can be used to disconnect calls with high error<br />

rates.<br />

If the call is not disconnected, the operator can trace the call in<br />

the networks.<br />

! This field is active only if the duration of the test is<br />

not CONTINUOUS.<br />

By examining the test results, the operator can i<strong>de</strong>ntify the<br />

<strong>de</strong>fective user access.<br />

This access can be controlled by making other measurement<br />

cycles and sampling the BER during a longer period of time.<br />

! If the Iftestko field is used, the instrument stops at<br />

the first failed cycle without disconnecting the call<br />

in progress.<br />

CHAPTER 12. SDN TERMINAL SIMULATOR 145