USER’S MANUAL REV. 5 <strong>ISDN</strong> <strong>ANALYZER</strong> <strong>D1080</strong><br />
8. MONITORING THE PHYSICAL LEVEL<br />
Regardless from the selected operating mo<strong>de</strong>, the instrument<br />
monitors and displays information about the physical level of the<br />
tested line.<br />
The groups of LED’s located in the front part of the instrument<br />
supply information about the state of the physical level of the<br />
connection, according to the type of access (either Basic or<br />
Primary).<br />
The LED’s located in the left column, marked as “TO TE", supply<br />
information about the Network → Terminal flow, while the LED’s<br />
located in the right column, marked as "TO NT", supply<br />
information about the Terminal → Network flow.<br />
When the TE TEST mo<strong>de</strong> is set, the instrument does not act as a<br />
user terminal, but as “NT”. In this case the meaning of the<br />
columns is reversed: the LED’s marked as “TO TE” refer to the<br />
Instrument → Terminal flow, while the LED’s marked as “TO NT”<br />
refer to the Terminal → Instrument flow.<br />
The instrument can be set to act as monitor in high impedance<br />
between network and user terminal, both in Basic and Primary<br />
Access.<br />
To do this, select the MONITOR mo<strong>de</strong> in the CONFIGURATION<br />
page (see Chapter 7).<br />
In this way the SIGNALLING PROTOCOL <strong>ANALYZER</strong> function can be<br />
accessed as well (see Chapter 10).<br />
CHAPTER 8. MONITORING THE PHYSICAL LEVEL 63