USER’S MANUAL REV. 5 <strong>ISDN</strong> <strong>ANALYZER</strong> <strong>D1080</strong><br />
There are two different types of activation for the physical level.<br />
The ‘cold’ activation occurs after switching on the instrument,<br />
after setting the ‘U’ interface in the CONFIGURATION or when the<br />
line voltage drops un<strong>de</strong>r the minimum value. The ‘warm’<br />
activation occurs in all the other situations. The difference<br />
between the two types is represented by the activation time,<br />
which is longer for the ‘cold’ activation. In case of line voltage<br />
lower than the minimum value, the energy consumption circuit is<br />
automatically disabled.<br />
These mo<strong>de</strong>s are implemented to simulate the standard operation<br />
of a NT.<br />
The activation/<strong>de</strong>activation time of the interface is automatically<br />
calculated for each activation (i.e. when the <strong>D1080</strong> is connected<br />
with the line for the first time and a call is ma<strong>de</strong>) and <strong>de</strong>activation<br />
of the line. The value is shown in the bottom of the display in<br />
milliseconds.<br />
The <strong>de</strong>activation time of the line cannot be measured over the<br />
Basic access with 4B3T co<strong>de</strong>, since this type of co<strong>de</strong> does not<br />
allow the measurement.<br />
9.1.4. Line<br />
Three fields are available which indicate the line voltage, the<br />
energy consumption of the instrument according to the set load<br />
and the binding resistance.<br />
The line energy consumption is with ‘constant power’ and<br />
therefore the current may vary according to the voltage.<br />
CHAPTER 9. “U” INTERFACE 77