<strong>ISDN</strong> <strong>ANALYZER</strong> <strong>D1080</strong> USER’S MANUAL REV. 5<br />
In Primary Access the quality tests can be executed while several<br />
calls to the network are active (see Paragraph 11.1.7). This makes<br />
it possible to check if the problems are due to specific channels<br />
or heavy traffic.<br />
While executing the quality tests, the instrument can receive and<br />
loop incoming calls (see Chapter 6).<br />
! In the SETTING UP menu the CallsRx field can be<br />
146<br />
configured with:<br />
NOT ACCEPTED<br />
ONLY COMPATIBLE<br />
ALL ACCEPTED<br />
The field must be set with ONLY COMPATIBLE or ALL<br />
ACCEPTED in or<strong>de</strong>r to loop the incoming calls.<br />
12.2.1.1. 64 kb – one B channel<br />
This makes it possible to test a single network section and<br />
i<strong>de</strong>ntify the “noisiest” path. It is an “User-User” test.<br />
Two mo<strong>de</strong>s are available:<br />
by using a remote loop box.<br />
The received data is the sum of the transmitted and the<br />
received data.<br />
The operator can <strong>de</strong>termine if the network section is noisy,<br />
but he does not know if the upstream connection is noisier<br />
than the downstream connection, or vice versa.<br />
CHAPTER 12. <strong>ISDN</strong> TERMINAL SIMULATOR