12.11.2012 Views

ISDN ANALYZER D1080 - messkom.de

ISDN ANALYZER D1080 - messkom.de

ISDN ANALYZER D1080 - messkom.de

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ISDN</strong> <strong>ANALYZER</strong> <strong>D1080</strong> USER’S MANUAL REV. 5<br />

142<br />

analysis. The values can either be as recommen<strong>de</strong>d by CCITT<br />

or set by the operator.<br />

Duration, the duration of the test (continuous or set from 1<br />

to 65.535 minutes)<br />

Sequence, the pattern to be used, which can be selected<br />

from the following pseudorandom sequences:<br />

− 2 11 - 1 (CCITT O.152 Recom.)<br />

− 2 15 - 1 direct (CCITT O.151 Recom.) and inverted<br />

− user (1 octet)<br />

Ncycles, the number of call cycles to be executed. It is only<br />

valid for tests with non-continuous duration and for tests of<br />

type “1 OUTGOING”.<br />

Pause, the pause between two measuring cycles. It is only<br />

valid if more calls cycles are set.<br />

Print, the possibility of printing the result page in various<br />

mo<strong>de</strong>s (see Paragraph 11.2.2)<br />

During the test both the information about the state of the call<br />

and the data about the test are displayed.<br />

As regards the call, the following information is displayed:<br />

the state of the call<br />

the called/connected number and subaddress<br />

the date and the starting time of the test<br />

the elapsed time of the test<br />

CHAPTER 12. <strong>ISDN</strong> TERMINAL SIMULATOR