<strong>ISDN</strong> <strong>ANALYZER</strong> <strong>D1080</strong> USER’S MANUAL REV. 5<br />
During the test the instrument checks the incoming and outgoing<br />
signals and gives information about the state of the call. The<br />
following tests are possible:<br />
178<br />
transmission of a pseudorandom pattern<br />
automatic answer with data loop over the used B channel<br />
making and/or answering up to 30 calls at the same time<br />
automatic generation of calls<br />
16.2.1. Pseudorandom transmission<br />
To set this test, press the functional button that corresponds to<br />
BERT in the main menu.<br />
The instrument generates a call to the tested terminal. Once<br />
connected, it transmits a pseudorandom pattern chosen between<br />
the standard sequences 2047, 32767 inverted and USER. If the<br />
terminal can loop the B channels, a quality measurement can be<br />
ma<strong>de</strong> by checking the presence of phase losses or errored bits on<br />
the display. To generate the call, set the OUTGOING mo<strong>de</strong> in the<br />
Call field.<br />
16.2.2. Automatic answer<br />
The instrument can be set to answer automatically to incoming<br />
calls. When a call is received, the instrument automatically sends<br />
the CONNECT message and loops the B channel used for<br />
connection.<br />
CHAPTER 16. <strong>ISDN</strong> TERMINAL TEST