USER’S MANUAL REV. 5 <strong>ISDN</strong> <strong>ANALYZER</strong> <strong>D1080</strong><br />

18. STATUS OF B CHANNELS<br />

This page can only be activated when the instrument is configured<br />

as SIMULATOR or TE TEST.<br />

This menu indicates the state of all B channels connected by the<br />

instruments.<br />

The LOOPED channels refer to incoming calls that were<br />

automatically answered by the instrument.<br />

The connected number is displayed for each incoming call.<br />

The B channel used by the instrument for the tests is i<strong>de</strong>ntified as<br />

“TEST RUN MODE”.<br />

! Over the S-BUS (B.R.A.) the instrument is not able to<br />

indicate the B channels used by other terminals<br />

connected to the bus.<br />

To disconnect a B LOOPED channel, select the corresponding line<br />

and press .<br />

18.1. RESTART<br />

This page is used to expressly request the RESTART to the<br />

network or the tested exchange. In or<strong>de</strong>r to do this, select the<br />

Restart field and indicate whether the RESTART refers to a specific<br />

B channel or to the entire interface.<br />

The instrument indicates the progress of the request.<br />