12.07.2015 Views

Environmental Statement volume 4 - Chiltern Evergreen3

Environmental Statement volume 4 - Chiltern Evergreen3

Environmental Statement volume 4 - Chiltern Evergreen3

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

noise level together with the duration of the activity will also be taken into accountin the assessment.4.2.7 BS5228 gives guidance on the significance of various vibration levels fromconstruction activities. Whilst guidance also exists in BS 6472, the advice in BS5228suggests that BS 6472 is not the best approach for assessing the disturbance effectstemporary construction work. Instead, BS 5228 suggests significance criteria interms of the PPV parameter. This parameter is proposed since it is routinelymeasured where potential building damage is a concern and empirical predictionsmethods are available in terms of the parameter.4.2.8 A summary of the relevant criteria for assessing the impact of vibration duringconstruction is provided below in Table 4.2. These criteria are applicable to allvibration sensitive receptors.Table 4.2Criteria for Evaluating the Significance of Vibration during ConstructionPeriod Building/Location Criterion PurposeAnytime Inside dwellings 0.3 mms -1 PPV (a )(b) Threshold of Perception(Negligible Effect below 0.3mms -1 )(from 0.3 to 1.0 mms -1 PPV =slight effect which isinsignificant)Anytime Inside dwellings 1.0 mms -1 PPV Complaints likely inresidential area, but can betolerated if prior warning andexplanation has been given tothe residents(above 1.0 mms -1 = ModerateEffect)Anytime Inside dwellings 10.0 mms -1 PPV Vibration is likely to beintolerable for any more thana very brief exposure to thislevel.(Major Effect)AnytimeAnytimeReinforced or framedstructures and heavycommercial buildingsUn-reinforced or lightframed structures.Residential or lightcommercial buildings.50 mms -1 PPV Protection of buildingstructure. Levels above areMajor Effects, and levelsbelow these are Negligible.15 mms -1 PPV Protection of buildingstructure. Levels above areMajor Effects, and levelsbelow these are Negligible.(a) PPV denotes peak particle velocity, as given in BS 7385 Part 2, 1993.(b) Equipment manufacturers should be consulted where equipment malfunction has seriousconsequences.ENVIRONMENTAL RESOURCES MANAGEMENT43CHILTERN RAILWAYS LTD

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!