About Status Variables for Conditions<br />

Configuring OVO<br />

Configuring Flexible Management Templates<br />

Status variables for conditions allow you to enable and disable conditions<br />

dynamically. The conditions are used in conditions for message target<br />

rules, and must be declared at be beginning of the template, after the<br />

TIMETEMPLATES values.<br />

OVO enables you to declare several variables for one condition, as well as<br />

declare one variable in several conditions. For example, an external<br />

interface can set the state of many conditions with one call.<br />

The following abbreviated (...) example of a template defining service<br />

hours sets the condition status variable for SAP to true:<br />

TIMETEMPLATES<br />

...<br />

CONDSTATUSVARS<br />

...<br />

RESPMGRCONFIG<br />

...<br />

CONDSTATUSVAR "sap" True<br />

MESSAGETARGETRULECONDS<br />

MESSAGETARGETRULECOND<br />

APPLICATION "Sap"<br />

DESCRIPTION "Filter SAP messages"<br />

CONDSTATUSVAR "sap"<br />

MSGOPERATIONS<br />

MSGOPERATION<br />

INSERVICE<br />

NOTE Status variables are persistent. They are not affected by the message<br />