13.12.2012 Views

HP OpenView Operations Administrator's Reference - filibeto.org

HP OpenView Operations Administrator's Reference - filibeto.org

HP OpenView Operations Administrator's Reference - filibeto.org

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Tuning and Troubleshooting OVO<br />

Solving Runtime Problems on All Managed Nodes<br />

434<br />

Problem D<br />

When any kind of application is started (Window (Input/Output),<br />

Window (Output Only), No Window) the calling user’s profile is<br />

executed. If the overall execution takes more than 2 seconds, or if the<br />

execution completes before anything is written to standard output, OVO<br />

assumes that an error has occurred and the application startup is<br />

terminated.<br />

Solution D<br />

Simplify the user’s profile so that it executes faster or writes more<br />

information to standard output. Also, make sure that the user’s profile<br />

does not prompt for specific input.<br />

Problem E<br />

The command path length (inclusive of parameters) is too long for an<br />

application configured as having a Window (Input/Output). Only 70<br />

characters are available for command path and resolved parameters<br />

(such as $OPC_NODES).<br />

Solution E<br />

Do not specify the full command path. Put this path in the executing<br />

user’s PATH variable. Avoid hard-coded parameters and only pass<br />

dynamic parameters. Instead of calling the application with lots of<br />

hard-coded parameters, use a script that internally calls the application<br />

with the required parameters. Instead of configuring this application to<br />

run in a Window (Input/Output), set this option to No Window, and<br />

start an hpterm/xterm on that managed node.<br />

Chapter 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!