Tuning and Troubleshooting OVO<br />

Solving Runtime Problems on MPE/iX Managed Nodes<br />

452<br />

If a Critical Error Message 30-511 Displays During<br />

Scheduled Actions<br />

Critical error message 30-511 when executing scheduled actions.<br />

Problem<br />

The output of the scheduled action cannot be read correctly.<br />

Solution<br />

The scheduled action executes correctly; you can safely ignore this error<br />

message.<br />

If Setting the Port Range for MPE/iX Managed Nodes<br />

Has No Effect<br />

Setting the port range for MPE/iX managed nodes has no effect.<br />

Problem<br />

You can set the port range in the Node Communication Options window,<br />

but this doesn’t have any effect. MPE/iX managed nodes cannot<br />

communicate with the OVO management server through a firewall.<br />

Solution<br />

There is no workaround available.<br />