Tuning and Troubleshooting OVO<br />

Solving Problems with the Embedded Performance Component<br />

Running the Embedded Performance Component<br />

under an Alternative User<br />

Problem<br />

If you run the embedded performance component process coda on<br />

HTTPS-based managed nodes under a user other than root and coda is<br />

configured to use the default port 381, coda will not start.<br />

Description<br />

The well-known ports from 0 through 1023 on most systems can only be<br />

used by system (or root) processes or by programs executed by privileged<br />

users. If coda does not run under root, it is not allowed to access<br />

port 381.<br />

Solution<br />

The solution to this problem depends on whether you need a fixed port<br />

for coda or whether you can run coda without a specified port number:<br />

❏ With fixed port<br />

Configure coda to use a port number higher than 1024, for example<br />

port 50381:<br />

ovconfchg -ns coda.comm -set SERVER_PORT 50381<br />

❏ Without fixed port<br />

Let the operating system automatically assign the next available<br />

port number to coda:<br />

ovconfchg -ns coda.comm -set SERVER_PORT 0<br />